Retractable Flap Barrier Operation Manual
21
- -
Refer to the slave control panel display (CLO2) when adjusting this parameter;
The value is 0-50;
dP06 : Gate open 2 Fine adjustment
Refer to the slave control panel display (OPE2) when adjusting this parameter; the
host display (OU01);
The value is 0-50;
dP07 : Gate open 1 Fine adjustment
Refer to the slave control panel display (OPE1) when adjusting this parameter; the
host display (IN01);
The value is 0-50;
dP08: minimum operating speed of the gate
The value is 0-10; the higher the value, the higher the speed;
dP09 : 00 without clutch; 01: with clutch (normally open);
Non-user menu:
Press and hold the INC button for about 2 seconds to display NP00; enter the non-
user menu
Users of this menu should not operate improperly, which will cause the equipment
to be inoperable; if it is necessary, please contact the company at the company's
technical personnel.
Under the guidance of the staff;
The meaning of the non-user menu is as follows:
NP00: Entry and exit of non-user menu (exit operation is the same as normal
menu)