Operation AERO GT ISOBUS
29
4
4.5.3
Calibration test
You perform the calibration test to calibrate the exact amount of fertiliser.
Fertiliser must be poured into the hopper. Calibration samples for up to 4 types
of fertiliser can be saved.
Execute the calibration test:
Before spreading for the first time.
If the fertiliser quality has changed significantly (moisture, high dust content,
grain breakage).
If a new type of fertiliser is used.
The calibration must be carried out either while the PTO shaft is running while the
tractor is stationary, or while driving on a test track.
1.
Call up the
Fertiliser settings > Start calibration
menu.
Figure 4.5:
Calibration test menu, page 1
[1] Fertiliser name
[2] Selection of the section width on which calibration test is carried out
2.
Enter the new name in the
Fertiliser name
input field.
3.
Select the desired section width for the calibration test.
To do this, put a tick under the section width number.
By default, the 3rd section width is selected.
4.
Press
OK
.
Page 2 appears.
5.
Enter the average working speed.
1
2