Operation AERO GT ISOBUS
4
26
4.5
Fertiliser settings
In this menu, you can make the fertiliser and spreading operation settings.
Open the menu
Main menu > Fertiliser settings
.
Figure 4.3:
Fertiliser settings menu, tabs 1 and 2
NOTICE
Not all parameters are displayed simultaneously on one screen. You can use the
left/right arrow keys
to jump to the adjacent menu window (tab).
Submenu
Meaning/possible values
Description
Fertiliser name
Fertiliser selected from the fertiliser chart
Application rate (kg/ha) Input of target value for the application
rate in kg/ha
Manufacturer
Enter the fertiliser manufacturer
Composition
Percentage of chemical composition
Turns/kg
Enter the turns of the metering units
Start calibration
Open the submenu for carrying out the
calibration
Fertiliser chart
Management of fertiliser charts