R&S ESU
Remote Control – Description of Commands
SENSe Subsystem
6.216
Operating Manual 1302.6163.12 - 03
[SENSe<1|2>:]SWEep:EGATe:LENGth
0 to 100 s
In case of edge triggering, this command determines the time interval during which the instrument
sweeps.
Example:
"SWE:EGAT:LENG 10ms"
Characteristics:
*RST value: 0s
SCPI: device-specific
Mode:
A
[SENSe<1|2>:]SWEep:EGATe:SOURce
EXTernal | IFPower
This command toggles between external gate signal and IF power signal as a signal source for the
gate mode. If an IF power signal is used, the gate is opened as soon as a signal at > -20 dBm is
detected within the IF path bandwidth.
Example:
"SWE:EGAT:SOUR IFP"
'Switches the gate source to IF power.
Characteristics:
*RST value: IFPower
SCPI: device-specific
Mode:
A
[SENSe<1|2>:]SWEep:EGATe:TRACe<1..3>COMMent
To enter a comment string in the gate range table.
The suffix after TRACe indicates the trace.
Example:
"SWE:EGAT:TRAC2:COMMent"
’To enter a comment in trace 2.
Characteristics:
*RST value: --
SCPI: device-specific
Mode:
A
[SENSe<1|2>:]SWEep:EGATe:TRACe<1..3>STATe<1..3>
ON | OFF
The gate range in the gate range table is set on or off.
The suffix after TRACe indicates the trace.
The suffix after STATe indicates the range.
Example:
"SWE:EGAT:TRAC2:STAT1 ON"
’Range 1 for trace 2 is switched on.
Characteristics:
*RST value: OFF
SCPI: device-specific
Mode:
A
Содержание 1129.7246.03
Страница 1: ...R S ESU EMI Test Receiver Operating Manual 1302 6163 12 03 Test Measurement Operating Manual ...
Страница 25: ......
Страница 27: ...R S ESU Putting into Operation 1 2 Operating Manual 1302 6163 12 03 ...
Страница 29: ...R S ESU Getting Started 2 2 Operating Manual 1302 6163 12 03 ...
Страница 31: ...R S ESU Manual Operation 3 2 Operating Manual 1302 6163 12 03 ...
Страница 349: ...R S ESU Instrument Functions Basic Settings 4 318 Operating Manual 1302 6163 12 03 ...
Страница 405: ...R S ESU Instrument Functions User Port 4 374 Operating Manual 1302 6163 12 03 ...
Страница 439: ...R S ESU Remote Control Basics Status Reporting System 5 34 Operating Manual 1302 6163 12 03 ...
Страница 821: ...R S ESU Remote Control Programming Examples More Complex Programming Examples 7 32 Operating Manual 1302 6163 12 03 ...
Страница 841: ...R S ESU Error Messages Device Specific Messages 9 10 Operating Manual 1302 6163 12 03 ...
Страница 854: ...Operating Manual 1302 6163 12 03 10 13 R S ESU ...
Страница 855: ...R S ESU 10 14 Operating Manual 1302 6163 12 03 ...