R&S ESU
Remote Control – Description of Commands
SENSe Subsystem
6.200
Operating Manual 1302.6163.12 - 03
Mode:
A-F
[SENSe<1|2>:]POWer:ACHannel:BANDwidth|BWIDth:ACHannel
100 Hz to 1000 MHz
This command defines the channel bandwidth of the adjacent channel of the radio transmission
system. If the bandwidth of the adjacent channel is changed, the bandwidths of all alternate adjacent
channels are automatically set to the same value.
With
SENS:POW:HSP ON
the steep-edged channel filters from the table "List of available channel
filters" in chapter
, section
“Setting the Bandwidths and Sweep Time – BW Key”
are available.
Example:
"POW:ACH:BWID:ACH 30kHz"
'Sets the bandwidth of all adjacent channels to 30 kHz.
Characteristics:
*RST value: 14 kHz
SCPI: device-specific
Mode:
A-F
[SENSe<1|2>:]POWer:ACHannel:BANDwidth|BWIDth:ALTernate<1...11>
100 Hz to 1000 MHz
This command defines the channel bandwidth of the alternate adjacent channels of the radio
transmission system. If the channel bandwidth of an alternate adjacent channel (e.g. channel no. 1) is
changed, the bandwidth of all the following alternate adjacent channels (e.g. channels no. 2 to 11) is
automatically set to the same value.
With
SENS:POW:HSP OFF
, the analog and FIR filters are available in the range from 10 Hz to 10 MHz.
With
SENS:POW:HSP ON
the steep-edged channel filters from the table "List of available channel
filters" in chapter
, section
“Setting the Bandwidths and Sweep Time – BW Key”
are available.
Example:
"POW:ACH:BWID:ALT2 30kHz"
Characteristics:
*RST value: 14 kHz
SCPI: device-specific
Mode:
A-F
[SENSe<1|2>:]POWer:ACHannel:FILTer:ALPHa:ALL
0…1
This command sets the rolloff factor of the RRC weighting filter for the TX channel, the adjacent
channel and all alternate channels as well. It is only available if Fast ACP is not active and no
predefined standard is selected. The query command is not supported..
Example:
"POW:ACH:FILT:ALPH:ALL 0.26"
'sets Alpha to 0.26
Characteristics:
*RST value: 0.26
SCPI: device-specific
Mode:
A
Содержание 1129.7246.03
Страница 1: ...R S ESU EMI Test Receiver Operating Manual 1302 6163 12 03 Test Measurement Operating Manual ...
Страница 25: ......
Страница 27: ...R S ESU Putting into Operation 1 2 Operating Manual 1302 6163 12 03 ...
Страница 29: ...R S ESU Getting Started 2 2 Operating Manual 1302 6163 12 03 ...
Страница 31: ...R S ESU Manual Operation 3 2 Operating Manual 1302 6163 12 03 ...
Страница 349: ...R S ESU Instrument Functions Basic Settings 4 318 Operating Manual 1302 6163 12 03 ...
Страница 405: ...R S ESU Instrument Functions User Port 4 374 Operating Manual 1302 6163 12 03 ...
Страница 439: ...R S ESU Remote Control Basics Status Reporting System 5 34 Operating Manual 1302 6163 12 03 ...
Страница 821: ...R S ESU Remote Control Programming Examples More Complex Programming Examples 7 32 Operating Manual 1302 6163 12 03 ...
Страница 841: ...R S ESU Error Messages Device Specific Messages 9 10 Operating Manual 1302 6163 12 03 ...
Страница 854: ...Operating Manual 1302 6163 12 03 10 13 R S ESU ...