Configuring the TCP Port Q.931 on the Scopia Elite MCU
The Scopia Elite 6000 Series MCU has designated port 1720 for Q.931. You can configure a
different port to use Q.931 (for example, if port 1720 is busy). Q.931 is a telephony protocol
used for establishing and terminating the connections in H.323 calls.
Procedure
Step 1
Navigate to the MCU Advanced Commands section by doing the following:
a.
Select the
icon.
b.
Select Advanced parameters.
c.
Locate the H323 SIG port number in the Name column (see
).
Figure 5-13
H.323 Signaling Port Configuration
Step 2
Select the
icon in the Review column.
Step 3
Enter the port value in the H323 SIG port number field.
Step 4
Select Apply.
Step 5
Select Close.
Configuring the TCP/UDP/TLS Port for SIP on the Scopia Elite MCU
The Scopia Elite 6000 Series MCU has designated ports 5060 and 5061 for SIP. You can
configure a different port to use SIP (for example, if port 5060 or 5061 is busy).
Procedure
Step 1
Navigate to the MCU SIP Protocol section by selecting Configuration > Protocols.
Step 2
Locate the Enable SIP protocol section and select More (see
).
RADVISION | Installation Guide for Scopia Elite 6000 Series MCU Version 8.0
Performing the MCU Initial Configuration | 42