Step 3
Select Enable SIP protocol to enable MCU communication with the SIP server.
Step 4
Enter the SIP domain of the MCU in the Default SIP domain field as defined in the SIP server.
An example of a SIP domain is company.com.
Step 5
Select Locate automatically to instruct the MCU to automatically locate one of the SIP
servers that are present in the domain,
or
Select Specify and enter the following:
•
An IP address or host name of the SIP server, for example <sipserver>.<company>.com.
Figure 5-5
SIP Protocol section of the Protocols tab
•
The communication port number of the SIP server address. The default port is 5060.
•
The protocol from the Type field. The default is UDP.
Note
The Locate automatically option works only if you have configured a valid IP address
at Configuration > Setup > Network > DNS server1 or DNS server2.
Step 6
To instruct the MCU to register with a SIP registrar and to send service information to the
registrar, perform these steps:
a.
Select Use registrar.
b.
Enter the following information:
•
The IP address or the host name of the SIP registrar in the IP address field.
•
The communication port number of the SIP registrar address.
•
The transport connection type for sending registration requests to the registrar
according to the type supported by the SIP registrar.
RADVISION | Installation Guide for Scopia Elite 6000 Series MCU Version 8.0
Performing the MCU Initial Configuration | 35