Procedure
Step 1
Navigate to the MCU Advanced Commands section by doing the following:
a.
Select the
icon.
b.
Select Advanced parameters.
c.
Locate Video Base Port or the Audio Base Port entry in the Name column to change the
video or audio port values respectively (see
).
Figure 5-8
Defining the base port for video
Step 2
Select the
icon in the Review column.
Step 3
Enter the new lower end port value in the field.
Step 4
elect Apply.
Step 5
elect Close.
Configuring the TCP Port Range for H.245 on the Scopia Elite MCU
The Scopia Elite 6000 Series MCU has designated TCP ports 1024-1324 for H.245. You can set
the base port, which is the lower end of the port range. H.245 is a Control Protocol used for
multimedia communication that enables transferring information about the device
capabilities, as well as opening/closing the logical channels that carry media streams.
The Scopia Elite 6000 Series MCU uses 300 ports.
Procedure
Step 1
Navigate to the MCU Advanced Commands section by doing the following:
a.
Select the
icon.
b.
Select Advanced parameters.
c.
Locate the CLI section and select More (see
).
RADVISION | Installation Guide for Scopia Elite 6000 Series MCU Version 8.0
Performing the MCU Initial Configuration | 38