2. FIRST START-UP
SUPPOR
T CENTER
PARAMETER
DESCRIPTION
RANGE
FUNCTION
P05
RECIRCULATION DIFFERENTIAL ACTIVATION
THROUGH THIS PARAMETER YOU CAN
ANTICIPATE THE RECIRCULATION
FUNCTION, COMPARED TO THE
RECIRCULATION SET POINT PRESET
BY THE END-USER, BY MODIFYING THE
TEMPERATURE DIFFERENCE.
5 - 15
VALUE EXPRESSED IN °C
P06
FAN MINIMUM SPEED ADJUSTMENT
THROUGH THIS PARAMETER YOU
CAN SET THE FAN MINIMUM SPEED
CORRESPONDING TO THE MINIMUM POWER
OF THE BURNER.
THE VALUE IS PRE-SET BASED ON THE SET
POWER (SEE PARAMETER P00) AND ON THE
GAS TYPE (SEE PARAMETER P01).
43 - 255
VALUE EXPRESSED IN HERTZ (1HZ = 30 RPM)
P07
FAN MAXIMUM SPEED ADJUSTMENT
THROUGH THIS PARAMETER YOU
CAN SET THE MAXIMUM FAN SPEED
CORRESPONDING TO THE MAXIMUM
POWER OF THE BURNER.
THE VALUE IS PRE-SET BASED ON THE SET
POWER (SEE PARAMETER P00) AND ON THE
GAS TYPE (SEE PARAMETER P01).
43 - 270
VALUE EXPRESSED IN HERTZ (1HZ = 30 RPM)
P08
STARTING STEP ADJUSTMENT
THROUGH THIS PARAMETER YOU CAN SET
THE FAN SPEED DURING THE START-UP.
THE VALUE IS PRE-SET BASED ON THE SET
POWER (SEE PARAMETER P00) AND ON THE
GAS TYPE (SEE PARAMETER P01).
43 - 255
VALUE EXPRESSED IN HERTZ (1HZ = 30 RPM)
P09
D.H.W RUN-DOWN
THROUGH THIS PARAMETER YOU CAN SET
THE TIME NECESSARY FOR THE WATER
HEATER TO REACH THE MINIMUM SET
POWER, AFTER THE BURNER START-UP.
02 - 15
VALUE EXPRESSED IN SECONDS (FACTORY SET AT 3
SECONDS)
P10
TYPE OF UNIT SELECTION
0 - 1
0 = °C - l/min
1 = °F - gpm
Содержание SFK 55
Страница 6: ......
Страница 32: ......
Страница 61: ...61 SFK 55 RAD ING Manual 1512 2_CSA_TTS 3 USE USER ...
Страница 62: ...62 SFK 55 RAD ING Manual 1512 2_CSA_TTS 3 USE USER ...
Страница 63: ...63 SFK 55 RAD ING Manual 1512 2_CSA_TTS 3 USE USER ...
Страница 64: ...64 SFK 55 RAD ING Manual 1512 2_CSA_TTS 3 USE USER ...
Страница 73: ......
Страница 74: ......
Страница 75: ......