SFK 55 - RAD - ING - Manual - 1512.2_CSA_TTS
2. FIRST START-UP
SUPPOR
T CENTER
2.1.5. PARAMETERS TABLE
PARAMETER
DESCRIPTION
RANGE
FUNCTION
P00
SELECTION OF THE FIRE RATING
0 - 3
0 = 24 KW
1 = 28 KW
2 = 34 KW
3= SFK 55 (55 KW)
P01
GAS TYPE SELECTION
ATTENTION:
READ THE INSTRUCTION IN CHAPTER ‘GAS
TRANSFORMATION’ BEFORE CHANGING
THIS PARAMETER.
0 - 1
0 = NATURAL GAS
1 = LPG
P02
WATER HEATER TYPE SELECTION
0 - 1
0 = ISTANTANEOUS
1 = STORAGE TANKLESS
P03
POST-CIRCULATION TIMING
(RECIRCULATION MODE NON ACTIVE)
THROUGH THIS PARAMETER YOU CAN SET
THE PUMP OPERATION DURATION ON THE
DOMESTIC CIRCUIT, AFTER THE TAP IS
CLOSED.
0 - 90
VALUE EXPRESSED IN MULTIPLES OF 5 SECONDS
(FACTORY SET AT 12 X 5 = 60 SECONDS)
P04
POST-CIRCULATION TIMING
(RECIRCULATION MODE ACTIVE)
THROUGH THIS PARAMETER YOU CAN
SET THE PUMP OPERATION DURATION
ON THE DOMESTIC CIRCUIT, WHEN THE
RECIRCULATION MODE IS ACTIVE, AFTER
THE TAP IS CLOSED.
0 - 90
VALUE EXPRESSED IN MULTIPLES OF 5 SECONDS
(FACTORY SET AT 8 X 5 = 40 SECONDS)
FIRST START-UP
Содержание SFK 55
Страница 6: ......
Страница 32: ......
Страница 61: ...61 SFK 55 RAD ING Manual 1512 2_CSA_TTS 3 USE USER ...
Страница 62: ...62 SFK 55 RAD ING Manual 1512 2_CSA_TTS 3 USE USER ...
Страница 63: ...63 SFK 55 RAD ING Manual 1512 2_CSA_TTS 3 USE USER ...
Страница 64: ...64 SFK 55 RAD ING Manual 1512 2_CSA_TTS 3 USE USER ...
Страница 73: ......
Страница 74: ......
Страница 75: ......