24
SFK 55 - RAD - ING - Manual - 1512.2_CSA_TTS
1. INSTALLATION
INST
ALLER
1.1.18. OPTIONAL ELECTRICAL
CONNECTIONS
The cables should be inserted inside the water
heater using the cable glands ‘P1’ and ‘P2’ placed
under the board (see fig. 17). Make a hole on the
cable gland, smaller than the cable diameter, to
make sure that the air cannot pass through.
To wire the optional below:
(TP) DOMESTIC HOT WATER PRE-HEATING
DEACTIVATION TIMER
use the terminal placed inside the control panel
as follows:
DANGER
Cut off the voltage from the main switch.
› remove the water heaters’s front casing (refer to
2.2.13 ACCESSING THE WATER HEATERS).
› unscrew the screws and remove plate “A” (see
fig. 18).
› After removing the plate, connect the electrical
cables to terminal “B” (see fig. 18);
› After performing these operations, remount
plate “A” and the front casing.
P1
P2
L
N
A
Rc
Rc
B
TP
INSTALLATION
fig. 18
fig. 17