1. INSTALLATION
INST
ALLER
1.1.15. GAS CONNECTION
WARNING
The gas piping must be installed
according to all local and state codes, or in absence
of local and state codes, with the latest “Natural
gas and propane installation code”, CAN/CSA-B
149.1 or “National Fuel Gas Code”, ANSI Z223.1
(NFPA 54). Consult the “Natural gas and propane
installation code” or “National Fuel Gas Code” for
the recommended gas pipe size of other materials.
BEFORE PERFORMING THE GAS CONNECTION,
MAKE SURE THAT:
› the gas line size and length meets requested
capacity;
› the gas line is equipped with all safety and
control devices required by the standards in
force;
› the internal and external seals of the gas inlet
lines of the unit are checked;
› the unit is suitable for use with the type of gas
available by checking the water heater data
plate (located on the inner side of the front
casing. If they do not match you must take the
necessary measures to adapt the water heater
to another type of gas (see 2.2.17 CONVERSION
TO A DIFFERENT GAS TYPE);
› the gas supply pressure falls within the values
indicated on the data plate.
1.1.16. ELECTRICAL CONNECTION
DANGER
The equipment is electrically safe only
if it is properly connected to an efficient grounding
system, performed in compliance with the safety
standards in force (National Electrical Code, ANSI/
NFPA 70 and or the Canadian Electrical Code Part
I, CSA C22.1, Electrical Code). You should check
this essential safety requirement. If in doubt,
request an accurate check of the electrical system
performed by qualified staff, as the manufacturer
is not responsible for any damages caused by lack
of grounding system.
› Make sure that the electrical systems is
suitable for the maximum power consumed by
the equipment, value indicated on the data plate.
› make sure that the cables section is appropriate
for the maximum power consumed by the
equipment.
› The equipment works with alternating current
of 120 V and 60 Hz. The electrical connection
must be installed using an all-pole switch with
an opening of at least 0.12 in (3 mm) between
contacts placed upstream from the device.
WARNING
Make sure that the phase and neutral
cables connection is installed in compliance with
the wiring diagram (see 1.1.16 POWER SUPPLY).
WARNING
It is strictly forbidden to use adaptors,
multiple plugs and/or extensions for the general
power supply of the equipment from the electrical
supply.
INSTALLATION
Содержание SFK 55
Страница 6: ......
Страница 32: ......
Страница 61: ...61 SFK 55 RAD ING Manual 1512 2_CSA_TTS 3 USE USER ...
Страница 62: ...62 SFK 55 RAD ING Manual 1512 2_CSA_TTS 3 USE USER ...
Страница 63: ...63 SFK 55 RAD ING Manual 1512 2_CSA_TTS 3 USE USER ...
Страница 64: ...64 SFK 55 RAD ING Manual 1512 2_CSA_TTS 3 USE USER ...
Страница 73: ......
Страница 74: ......
Страница 75: ......