SCPI Command Reference 4-10
Standard Waveform
Command Summary
The Standard Waveform Commands control the various parameters
of the standard output functions. Optional modes are omitted from
these commands. Factory defaults after *RST are shown in bold
typeface. Parameter low and high limits are given where applicable.
The Standard Waveforms parameters could be used for the APPLy
command.
Command and Parameters
Low Limit
High Limit
Default
[SOURce:]
SINusoid:PHASe <value>
0
360
0
SINusoid:PHASe?
SINusoid:POWer <value>
1
9
1
SINusoid:POWer?
TRIangle:PHASe <value>
0
360
0
TRIangle:PHASe?
TRIangle:POWer <value>
1
9
1
TRIangle:POWer?
SQUare:DCYCle <value>
1
99
50
SQUare:DCYCle?
PULSe:DELay <value>
0
99.9
10.0
PULSe:DELay?
PULSe:WIDTh <value>
0
99.9
10.0
PULSe:WIDTh?
PULSe:TRANsition <value>
0
99.9
10.0
PULSe:TRANsition?
PULSe:TRANsition:TRAiling <value>
0
99.9
10.0
PULSe:TRANsition:TRAiling?
RAMP:DELay <value>
0
99.9
10.0
RAMP:DELay?
RAMP:TRANsition <value>
0
99.9
10.0
RAMP:TRANsition?
RAMP:TRANsition:TRAiling <value>
0
99.9
10.0
RAMP:TRANsition:TRAiling?
SINC:NCYCle <value>
4
100
10
SINC:NCYCle?
GAUSsian:EXPonent <value>
1
200
10
GAUSsian:EXPonent?
EXPonential:EXPonent <value>
-200
200
-10
EXPonential:EXPonent?
DC <%_amplitude>
-100
100
100
DC?
Содержание 3152
Страница 16: ...Getting Started 1 7 Figure 1 1 Segment 1 Sin x x Waveform Figure 1 2 Segment 2 Sine Waveform...
Страница 25: ...Configuring The Instrument 2 6 This page was intentionally left blank...
Страница 63: ...Using The Instrument 3 38 This page was intentionally left blank...
Страница 80: ...SCPI Command Reference 4 17 Figure 4 1 SCPI Status Registers...
Страница 121: ...Specifications A 12 This page was intentionally left blank...