Getting Started 1-3
5.
407510-012 - Model 3152 - 100MS/s Waveform
Synthesizer, w/256K RAM, 1PPM
6.
407510-002 - Model 3152 - 100MS/s Waveform
Synthesizer, w/512K RAM, 1PPM
7.
407510-012 - Model 3152 - 100MS/s Waveform
Synthesizer, w/ 64K RAM, 100PPM
8.
407510-022 - Model 3152 - 100MS/s Waveform
Synthesizer, w/256K RAM, 100PPM
9.
407510-021 - Model 3152 - 100MS/s Waveform
Synthesizer, w/512K RAM, 100PPM
The 64K RAM option designates the memory size supplied with the
Model 3152. The standard memory size is 64K (65536 words).
With the standard memory size, 64536 point waveforms can be
programmed because 1K is allocated for standard waveforms.
The 256 suffix designates instruments supplied with 256K memory
expansion. With the 256K expansion, 261144 point waveforms can
be programmed.
The 512K RAM option designates instruments supplied with 512K
memory expansion. With the 512K expansion, 523288 point
waveforms can be programmed.
1ppm and 100ppm denote different accuracy and stability grades of
the internal 10 MHz reference clock. Normally, VXIbus modules
receive their clock reference from VXIbus CLK10. There are
applications that require complete separation from VXIbus clocks.
The crystal oscillator (100ppm) and TCXO (1ppm) options, when
installed, provide the required separation.
Manual Changes
Technical corrections to this manual (if any) are noted on the pages
themselves, with change dates at the bottom of the page.
Safety
Considerations
The Model 3152 has been manufactured according to international
safety standards. The instrument meets VDE 0411/03.81 and UL
1244 standards for safety of commercial electronic measuring and
test equipment for instruments with an exposed metal chassis that
is directly connected to earth via the chassis power supply cable.
.
WARNING
Do not remove instrument covers when operating or when
the chassis power cord is connected to the mains.
Any adjustment, maintenance and repair of an opened, powered-on
instrument should be avoided as much as possible, but when
necessary, should be carried out only by a skilled person who is
aware of the hazard involved.
Revised 4/18/00
Содержание 3152
Страница 16: ...Getting Started 1 7 Figure 1 1 Segment 1 Sin x x Waveform Figure 1 2 Segment 2 Sine Waveform...
Страница 25: ...Configuring The Instrument 2 6 This page was intentionally left blank...
Страница 63: ...Using The Instrument 3 38 This page was intentionally left blank...
Страница 80: ...SCPI Command Reference 4 17 Figure 4 1 SCPI Status Registers...
Страница 121: ...Specifications A 12 This page was intentionally left blank...