User Manual 2460 Series
Programming The 2461 Module 4-34
Racal Instruments
2003
Byte Request
The ‘master’ uses this command to receive a data byte from a ‘slave’ instrument.
Command:
AEFF
16
The response is placed in the Data Low Register. The END field indicates the last byte of
the message.
Response:
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
1
0
1
1
1
1
0
END
DATA
Clear
This command is used by a ‘master’ to force a ‘slave’ to re-initialize the VXI interface and interrupt
all operations. Any operation underway when this command is received is terminated normally.
Command:
FFFF
16
Response:
No response