a
1
2
1
3
PAVO V140 / VHA 140
09.2011
Check the operating pressure of the
hydraulic system on the tractor.
Max. operating pressure = 210 bar
Turn off tractor hydraulic system or
switch to floating position (depressurise).
Connect hydraulic hoses according to
connection colours (see table).
During connection, make sure that the
lock on the hydraulic connection audibly
engages.
Open the hydraulic system on the tractor.
►
►
►
►
Connecting the supply
Fig. 23: Hydraulic connections
7.2 Connecting the PAVOtronic
Route the 7-pole connector of the control
cable (
1
) to the tower of the PAVO.
When routing the cable, make sure that
it is protected in cable ducts.
Connect the connector to the connection
socket (
2
) and secure by screwing
the coupling cap (
a
) into place (splash
guard).
Connect the connector for
the PAVOtronic's power supply (
3
) to
the three-pole socket (DIn 9680) on
the tractor.
NOtE
Do not use an adapter cable
for the power connection to
the windscreen wiper socket
(DIn 72591).
If an adapter cable is used, there
is no guarantee that the unit will
function properly.
►
►
►
Fig. 24: PAVOtronic connections
Содержание Pavo V 140
Страница 1: ...EN Operating Instructions Serial no Pavo V 140 PAVO VHA 140 with PAVOtronic Series 1...
Страница 4: ...PAVO V140 VHA 140 09 2011...
Страница 18: ...18 PAVO V140 VHA 140 09 2011...
Страница 99: ...99 PAVO V140 VHA 140 09 2011 EU Declaration of Conformity Declaration of Conformity...
Страница 100: ...100 PAVO V140 VHA 140 09 2011...