To edit an item, highlight the appropriate line and then press and hold the encoder
until the command is accepted. This way, Pwr setting is toggled between On and
Off and Mod setting is toggled between “x1” and “x10”. To edit the Power Good
rate, simply select item “PgD” or “PgR” and edit its value and press the ecnoder
to confirm.
Menu 4
Pwr
Enables (ON) or disables (OFF) exciter power output.
Mod
Modifies modulation display (toggles between “x1” and “x10”). In “x10”
mode, instantaneous deviation indication is multiplied by a factor of 10,
and the bar meter on the default menu will reflect 7.5 kHz instead of
75 kHz. This display mode is convenient when you wish to display low
deviation levels, such as those caused by pilot tone or subcarriers.
PgD
M Regulation of the Power Good threshold relative to the forward power.
The percentage value of Power Good is referred to the nominal power
of the machine, that is 30/50 W, not to the supplied forward power. If a
value equal to 50% is setted, it will correspond indifferently to 15/25 W
from the set up power. The Power Good function is a control and alarm
function on the supplied power. When the output power fall under the
threshold value of Power Good set, the machine modifies the pin state
[7] of “Remote” DB15 connector on the rear panel.
PgR
M Regulation of the Power Good threshold relative to the forward power.
The percentage value of Power Good is referred to the nominal power
of the machine, that is 10W, not to the supplied forward power.If a value
equal to 5% is set, it will correspond to 0,5 W indifferently from the set
up power.
NOTE:
This alarm does not have effect on any output signal on the DB15 “Remote”
connector, and it works only in presence of systems equipped of telemetry
.
Exit
The entry allows to the user the prompt exit from current submenu and
goes back to the
predefined menu
.