BLUES30/50NV
ELETTRONICA
21
/ 28
User Manual
Rev. 1.0 - 29/11/16
dTa
Regulation of exchange time between digital and analog.
Exit
The entry allows to the user the prompt exit from current submenu and
goes back to the
predefined menu
.
5.4.5 Miscellaneous Menu (Mix)
This menu allows you to set the machine’s address in a serial bus connection (I
2
C
type).
The FSK function, generates periodic shifts of the transmission carrier frequency,
realizes in way to generate a Morse code that carried the Radio Identification
Code.
NOTE:
This function is tipically used in the United States.
The factory setting for frequency shift is +10KHz and code repetition period is
60 minutes (please contact R.V.R. Elettronica if you need different settings),
whereas station identified may be programmed by the user following the indications
described below.
Menu 8
IIC
Regulation of the I
2
C address. The I2C network address is important
when the exciter is connected to a company’s transmission system
that envisages use of this protocol. We recommend you do not modify
it without a good reason.
FSK
Enable or disable the transmission of the FSK code.
Cod
Regulation of the code normally transmitted.
Exit
The entry allows to the user the prompt exit from current submenu and
goes back to the
predefined menu
.
5.4.6 Version Menu (Vrs)
This screen shows the version and the release date of the software: