BLUES30/50NV
ELETTRONICA
23
/ 28
User Manual
Rev. 1.0 - 29/11/16
5.5 Optional Functions
Optional functions can be added and/or modified for the equipment described in
this manual. The available functions are carried in the continuation and can be
requested to R.V.R. Elettronica at the moment of the order.
5.5.1 UP/DOWN Power Option
The UP/DOWN Power modifies the function to receive signals present on the
telemetry connector.
In this particular situation the control signals uses to enable or to disable the RF
section, become control signals of the RF power level, allowing one regulation of
UP/DOWN type.
The UP or DOWN command is supplied connecting the relative signal on the
Remote connector to the ground, at least for 500mS (the pin has an inner pull-up
towards feeding).
Configuration of the telemetry DB15F connector (Remote):
Pin Standard Function
UP/DOWN Power Function
14 On cmd
Up cmd
Enables RF power supply
Increases RF the Power supply
15 Off cmd
Down cmd
Disables RF power supply
Reduces RF the Power supply