5.6. ESD Protection
Static electricity occurs naturally and it may damage the module. Therefore, applying proper ESD
countermeasures and handling methods is imperative. For example, wear anti-static gloves during the
development, production, assembly and testing of the module; add ESD protection components to the
ESD sensitive interfaces and points in the product design.
Table 43: Electrostatic Discharge Characteristics (Temperature: 25
–30 °C, Humidity: 40 ±5 %)
LTE-TDD B48 CH55590 @ 21.88 dBm
305.05
mA
WCDMA
WCDMA B1 CH10700 @ 24.52 dBm
739.17
mA
WCDMA B2 CH9800 @ 24.25 dBm
648.81
mA
WCDMA B3 CH1338 @ 24.18 dBm
680.93
mA
WCDMA B4 CH1638 @ 24.41 dBm
788.8
mA
WCDMA B5 CH4407 @ 23.85 dBm
577.69
mA
WCDMA B6 CH4400 @ 23.84 dBm
578.14
mA
WCDMA B8 CH3012 @ 23.89 dBm
635.27
mA
WCDMA B19 CH738 @ 23.83 dBm
566.84
mA
Tested Interface
Contact Discharge
Air Discharge
Unit
VCC, GND
±5
±10
kV
Antenna Interfaces
±4
±8
kV
Other Interfaces
±0.5
±1
kV