30
Introduction
Connecting the Door Switch Loop Cable
In all modules except for the left parking module, the door interlock switch is connected via a cable to that
module’s LBX board. Since the left parking module does not have an LBX board, its door interlock switch
shares the connection with the control module’s door interlock switch. The Gen 2 door switch loop cable
facilitates this sharing. The single end plugs into the LBX board in the control module, and the two
connectors on the “Y” end connect to the door interlock switch connectors in the control module and in the
left parking module. The two ends that connects to the CM LBX board and the CM door interlock cable are
pre-installed. The only thing you need to do is connect the one end of the “Y” that connects to the left parking
module.
Figure 12
Door Switch Loop Cable - Picture for reference only. The cable will NOT be loose; it will be
partially pre-installed in the left parking module
Required tools: None
Required equipment: Door switch loop cable (FRU ID number:
841) (partially installed in control module)
1
Find the door switch loop cable in the control module. One connector on the 2-connector end is already
attached to the CM door interlock cable and the long end is already pre-connected to the LBX board in
the control module. The door switch loop cable should be visible in the open area above the power
chassis. See
Figure 13
.
Preinstalled:
Connected to LBX
board in control module
Preinstalled: Connected
to control module door
interlock cable
Connect to
door switch
interlock
cable in left
parking
module
Содержание Scalar i6000
Страница 14: ...14 Introduction Figure 1 Power Rail Position in Module Two bridge clamps connect adjacent rails...
Страница 15: ...Scalar i6000 Installation Guide Super Doc 15 Figure 2 Power Rail Front 4 pin and 3 pin connectors...
Страница 23: ...Scalar i6000 Installation Guide Super Doc 23 Figure 6 Installing Bottom and Middle Racks...
Страница 24: ...24 Introduction Figure 7 Middle X Axis Gear Rack...