Chapter 4 SCSI Commands
LOG SENSE Command (4Dh)
DLT-S4 Interface Reference Guide
96
Figure 48 Cleaning-Related
Log Parameters Format for
Device Status
LOG SENSE
Page
DS
1
Disable Save.
TSD
any
Target Save Disable. When set to zero indicates the parameter is saved
periodically. When set to one the parameter is not saved.
ETC
0
Enable Threshold Comparison.
TMC
0
Threshold Met Criteria.
LBIN
any
List Binary. When set to zero indicates the parameter value is in ASCII.
When set to one, indicates the parameter value is a binary number.
LP
any
List Parameter. When set o zero indicates the parameter value is a
counter. When set to one, indicates the parameter value is not a counter.
Parameter
Length
Specifies the number of bytes in the parameter value.
Parameter
Value
Indicates the actual value of this log parameter.
Bit
Byte
7
6
5
4
3
2
1
0
4
Reserved
ClnQ
ClnR
ClnEx
5 — 7
(MSB)
Reserved
(LSB)
Field
Description