Chapter 4 SCSI Commands
REQUEST SENSE Command (03h)
DLT-S4 Interface Reference Guide
311
NO SENSE
(continued)
00h
5Dh
00h
TapeAlert Failure Prediction Threshold Exceeded
5Dh
FFh
False Exception Condition
RECOVERED
ERROR
01h
00h
17h
Clean Requested (Non-Vendor Specific)
0Ah
00h
Error Log Overflow
0Ah
80h
Error Log Generated
37h
00h
Rounded Parameter
3Bh
08h
Repositioning Error
44h
C1h
EEPROM Copy 1 Area Bad
44h
C2h
EEPROM Copy 2 Area Bad
47h
00h
SCSI Parity Error
48h
00h
IDE Message Received
51h
00h
ERASE Failure
53h
01h
Unload Tape Failure
5Bh
01h
Threshold Condition Met
5Bh
02h
Log Counter at Maximum
5Dh
00h
Failure Predictive Threshold Exceeded
5Dh
FFh
Failure Predictive Threshold Exceeded (False)
NOT READY
02h
04h
00h
Unit Not Ready, Cause Nonreportable
04h
01h
Unit Not Ready, Calibration in Process
04h
02h
Unit Not Ready, LOAD Command Needed. A tape
cartridge is loaded but the tape medium is in an unloaded
state.
04h
03h
Unit Not Ready, Manual Intervention Needed. No tape
cartridge is present or a mechanical failure has occurred.
04h
07h
Unit Not Ready, Loader Operation in Progress
25h
90h
Bad Code Update Image Header
30h
00h
Incompatible Medium Installed
30h
02h
Incompatible Format
30h
03h
Cleaning Cartridge Installed
3Ah
00h
Medium Not Present
3Eh
00h
Logical Unit Has Not Self-Configured Yet
Text Name
Sense
Key
ASC
ASCQ Description