Chapter 4 SCSI Commands
LOG SENSE Command (4Dh)
DLT-S4 Interface Reference Guide
78
Figure 36 Log Parameters
Format for Temperature Page
Table 48 Temperature
LOG
SENSE
Parameters
Bit
Byte
7
6
5
4
3
2
1
0
0 — 1
(MSB)
Parameter Code (Temperature)
(LSB)
2
DU
DS
TSD
ETC
TMC
LBIN
LP
3
Parameter Length (02h)
4 — 5
(MSB)
Parameter Value
(LSB)
Field
Description
Parameter
Code
Parameter codes supported for the Temperature page are as follows:
Code
Description
0000h
Current operating temperature (degrees Celsius).
0001h
Reference temperature (degrees Celsius). This is the maximum reported
sensor temperature at which the tape drive is capable of operating
continuously without experiencing degradation beyond the limits, specified
in the
DLT-S4 Product Manual
for this product.
Parameter
Control Byte
Bit
Value
Description
DU
0
Disable Update.
DS
1
Disable Save.
TSD
0
Target Save Disable.
ETC
0
Enable Threshold Comparison.
TMC
0
Threshold Met Criteria. Ignored.