Chapter 4 SCSI Commands
MODE SENSE (6) / (10) Command (1Ah / 5Ah)
DLT-S4 Interface Reference Guide
166
Table 94
Parallel SCSI
—
Disconnect / Reconnect
MODE
SENSE
Page — Field
Descriptions
6 — 7
(MSB)
Disconnect Time Limit (0)
(LSB)
8 — 9
(MSB)
Connect Time Limit (0)
(LSB)
10 — 11
(MSB)
Maximum Burst Size
(LSB)
12
EMDP (0)
Fair Arbitration (0)
DIMM (0)
DTDC
13
Reserved
14 — 15
(MSB)
Reserved
(LSB)
Field
Description
PS
Parameters Savable. Always set to 0.
SPF
SubPage Format. Always set to 0. Indicates that this page uses the page_0 page
format.
Page Code
Identifies the type of
MODE SENSE
page being transferred. A value of 02h
identifies this as the Disconnect / Reconnect Page.
Page Length
Indicates the number of bytes in the page, excluding bytes 0 and 1.
Buffer Full Ratio
Always set to 0.
Buffer Empty Ratio
Always set to 0.
Bit
7
6
5
4
3
2
1
0
Byte