![Quantum DLT-S4 Скачать руководство пользователя страница 85](http://html2.mh-extra.com/html/quantum/dlt-s4/dlt-s4_reference-manual_3531879085.webp)
Chapter 4 SCSI Commands
INQUIRY Command (12h)
DLT-S4 Interface Reference Guide
51
Firmware Build Information Page (C0h)
4
Figure 18
shows the format of the Firmware Build Information page the
drive returns.
Figure 18 Firmware Build
Information Page — Data
Format
Table 28 Firmware Build
Information Page — Field
Descriptions
Bit
Byte
7
6
5
4
3
2
1
0
0
Peripheral Qualifier
Peripheral Device Type
1
Page Code (C0h)
2
Reserved
WORM
3
Page Length (28h)
4 — 7
Servo Firmware Revision
8 — 11
Servo Firmware Checksum
12 — 15
Servo EEPROM Checksum
16 — 19
Controller Firmware Checksum
20 — 43
Controller Firmware Build Date
Field
Description
WORM
The Write Once, Read Many (WORM) bit indicates if the device is
capable of supporting this mode. This bit is always set to 1.
Servo Firmware Revision
Contains the revision number of the servo firmware.
Checksum
The Servo Firmware, Servo EEPROM, and
READ
/
WRITE
Firmware
checksums are binary numbers used for positive firmware and
EEPROM identification.
Controller Firmware Build
Date
Firmware Build Date. An ASCII string in DD-MM-YYYY HH:MM:SS
format.