Chapter 4 SCSI Commands
MODE SELECT (6) / (10) Command (15h / 55h)
DLT-S4 Interface Reference Guide
124
Figure 65
Parallel SCSI
—
Logical Unit Control
MODE
SELECT
Page — Data Format
Table 74
Parallel SCSI
—
Logical Unit Control
MODE
SELECT
Page — Field
Descriptions
Bit
7
6
5
4
3
2
1
0
Byte
0
PS (0)
SPF (0)
Page Code (18h)
1
Page Length (06h)
2
Reserved
Protocol Identifier (1h)
3 — 7
Reserved
Field
Description
PS
Parameters Savable. Must be set to 0.
SPF
SubPage Format. Always set to 0. Indicates that this page uses the page_0 page
format.
Page Code
Identifies the type of
MODE SELECT
page being transferred. A value of 18h
identifies this as the Logical Unit Control Page.
Page Length
Indicates the number of bytes in the page, excluding bytes 0 and 1. The length is
returned on
MODE SENSE
and must subsequently be set to the same value when
performing
MODE SELECT
.
Protocol
Identifier
A value of 1h indicates that this mode page applies to an SPI-5 compliant port (see
the
SCSI Parallel Interface - 5
(SPI-5) standard).