background image

4. If filler section is desired to terminate the heater, install the

filler section in the end of the heater and extend to desired
length.  Mark the mounting hole locations, remove the filler
section and drill the required mounting holes.  Install the filler
section in the heater and the end cap on the filler section as
shown in Figure 2.

Note:  If a thermostat and/or disconnect switch are installed in
the heater left junction box, it may be necessary to cut away a
portion of the filler section to allow access to these controls
(Figure 2).

5 Position heater housing on wall to check for evenness of

wall.  do not draw the heater against an uneven wall surface.
If an uneven wall is encountered, use shims to keep the
heater housing straight.

6. Run proper size branch circuit to the junction box through the

selected knockout.

7. Drill the required size mounting holes in the back of the

heater housing and install the housing on the wall using
screws, bolts or anchors (by installer) to suit the wall con-
struction.

Note:  Predrilled 1/4” diameter mounting holes are provided in
each junction box.  Additional mounting holes will have to be
drilled in the housing to support the weight of long length
heaters (6’ and longer).  Do not drill any additional holes in the
junction boxes.

8.

Tighten mounting screws and back off 1/4 to 3/4 turn to
allow for expansion and contraction of the heater.

9.

Following the wiring diagram secured to the heater, make
electrical connections.  Ground the heater using the ground
screws provided (Figure 2).

10. Replace front cover and secure with mounting screws. (See

Figure 2).

Installation of Multiple Wall to Wall Units

Note: For ease of installation, it is important that the sequence
of operations indicated below be followed in order.

1. Remove all the front covers from the heaters by removing

mounting screws (Figure 2).

2. Refer to wiring diagram for power supply entry and remove

appropriate electrical knockout (Figure 3) from the heater in
which power supply connections are to be made. The power
supply may be brought in to the end of only one heater and
the remaining heaters may be connected in parallel using the
wireway.  Use Table B to size the field installed wiring in the
wireway.

3. If conduit cover (must be purchased separately) is desired,

cut off the appropriate length and install to  the wall.

4. If required by plan, install filler section (1, Figure 1) to either

heater (2) or (3) by means of four #6 screws supplied with
filler section.  (Refer to Figure 5.) Discard filler section end
cap in this application.

Note: Heaters may butt against each other, thus eliminating the
filler piece, if so desired.

Note:  If a heater has a disconnect switch and / or thermostat
and is to have a filler section or a corner section at the left end,
the section must be mounted to the heater since the thermostat
or disconnect switch will prevent the section from telescoping
into the heater.

5 If the wall run has inside or outside corners, install corner (4

and 5) to the heater (2 and 9) by means of four #6 screws
supplied with corner section.  (Refer to Figure 5).

6. Install end caps (6) on the outer end of the last heater(7) and

(9) using four #6 screws supplied with end caps.  (Refer to
Figure 4 for details of end cap installation.)

7. Drill the required size mounting holes in all the heater hous-

ings.

Figure 4

5

Figure 5

Содержание CSH05A

Страница 1: ...ing this heater 7 This heater is not for residential or household use CSH and DSH Convectors Installation Operation Maintenance Instructions Commercial Sill Height Convection Heaters Type CSH GENERAL...

Страница 2: ...ix with CSH05A 5 1 2 height heaters DSH05A 5 1 2 height heaters Model CSH05A DSH05A H 5 1 2 D 3 Table A Table A continued Amperage Catalog Length Total 208V 240V 277V Number L Watts Ft Watts 1 3 1 3 1...

Страница 3: ...ishings Away From Heater For effi cient and safe operation we recommend maintaining a min imum of 6 inches 152 mm clearance above and in front of the heater at all times See Clearances Chart for minim...

Страница 4: ...Minimum mounting heights above the floor shall be as follows Minimum Mounting Height Above Floor Watts Ft Heater Length Bottom Inlet Front Inlet 125 188 and 250 Watts Ft 1 3 4 0 376 500 625 and 750 3...

Страница 5: ...with mounting screws See Figure 2 Installation of Multiple Wall to Wall Units Note For ease of installation it is important that the sequence of operations indicated below be followed in order 1 Remo...

Страница 6: ...agram on control sections for connecting the wiring to the heaters Installation of Mullion to Mullion Units The back of the heater housing contains no mounting holes other than those at the ends and t...

Страница 7: ...s since these could damage the finish or discolor in use 2 A vacuum cleaner and or compressed air may be used to remove dust and lint that may have accumulated inside heater around element fins If hea...

Страница 8: ...8...

Страница 9: ...07A CSH14A Add suffix 1 for bottom inlet top outlet Add suffix 3 for bottom inlet front outlet Intended for the installation of components R Suffix on catalog number refers to accessories with 120 VAC...

Страница 10: ...Products THE ABOVE WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH EXCEED THE AFORESAID EXP...

Страница 11: ...o en el interruptor de desconexi n principal o panel de servicio 7 Este calefactor no es para uso residencial ni hogare o Calefactores de convecci n CSH y DSH Instrucciones de instalaci n operaci n y...

Страница 12: ...8125 125 1000 4 8 4 2 3 6 8188 8 188 1500 7 2 6 2 5 4 8250 250 2000 9 6 8 3 7 2 10125 125 1250 6 0 5 2 4 5 10188 10 188 1875 9 0 7 8 6 7 10250 250 2500 12 0 10 4 9 0 Prefijo con CSH05A calefactores c...

Страница 13: ...io 4 Antes de instalar o energizar el calefactor remueva y deseche el material de empaque de espuma colocado dentro del calefactor 5 No instale el calefactor contra superficies combustibles de tabla d...

Страница 14: ...portante seguir en orden la secuencia de operaciones indicada abajo 1 Remueva la cubierta delantera removiendo los tornillos de montaje Figura 2 2 Remueva la tapa precortada removible apropiada de cua...

Страница 15: ...aciones indicada abajo 1 1 Remueva todas las cubiertas delanteras de los calefactores removiendo los tornillos de montaje Figura 2 2 Consulte el diagrama de cableado para la entrada del alambre s de a...

Страница 16: ...bres a los calefactores Instalaci n de unidades de entreventana a entreventana miembro vertical intermedio en el marco de una ventana La parte trasera de la carcasa del calefactor no contiene orificio...

Страница 17: ...da ar las aletas 3 Despu s de limpiar y suministrar servicio de mantenimiento siempre reensamble colocando nuevamente cualquier herraje removido y revise las unidades para verificar que est n funcion...

Страница 18: ...Pie por elemento calefactor 250 W Pie por elemento calefactor Controles incorporados Opcional PANEL TRASERO PANEL TRASERO PANEL TRASERO REJILLA REJILLA REJILLA TERMOSTATO OPCIONAL TERMOSTATO OPCIONAL...

Страница 19: ...1 DSH14 BL4 1 DSH14 BL5 1 DSH14 BL6 1 DSH14 BL8 1 DSH14 BL10 1 DSH14 BCS SHCC 07 14 Adici n de longitud N N mero de cat logo CSH05A CSH07A CSH14A Agregue el sufijo 1 para entrada inferior por abajo sa...

Страница 20: ...ed Products LAS ANTERIORES GARANT AS REEMPLAZAN CUALQUIER OTRA GARANT A EXPRESA O IMPL CITA Y TODAS LAS GARANT AS IMPL CITAS DE MERCADE ABILIDAD Y ADECUADIBILIDAD PARA UN PROP SITO EN PARTICULAR QUE E...

Страница 21: ...diateur est bien d branch en amont l interrupteur g n ral ou au pan neau de service avant d intervenir pour installer ou d panner ce radiateur 7 Ce radiateur n est pas pour une utilisation r sidentiel...

Страница 22: ...25 1250 6 0 5 2 4 5 10188 10 188 1875 9 0 7 8 6 7 10250 250 2500 12 0 10 4 9 0 Pr fixe avec CSH05A radiateurs de 5 1 2 de haut CSH05A radiateurs de 5 1 2 de haut Mod les CSH05A DSH05A H 5 1 2 P 3 Tabl...

Страница 23: ...die 4 Enlevez de l int rieur du radiateur et mettez au rebut les mat riaux d emballage en mousse avant d installer le radiateur et de le mettre sous tension 5 N installez pas le radiateur contre des s...

Страница 24: ...t unique Remarque Pour faciliter l installation il est important que la s quence des op rations indiqu es ci apr s soit suivie dans l ordre 1 Enlevez le couvercle frontal en tant ses vis de fixation F...

Страница 25: ...quence des op rations indiqu es ci apr s soit suivie dans l ordre 1 Enlevez tous les couvercles frontaux des radiateurs en tant leurs vis de fixation Figure 2 2 R f rez vous au sch ma de c blage pour...

Страница 26: ...ils aux radiateurs Installation d unit de meneau meneau Le dos du carter de radiateur ne comporte pas de trous de montage autres que ceux dispos s aux extr mit s et de ce fait c est id al pour une ins...

Страница 27: ...yant les ailettes d l ment pour ne pas les abimer 3 Apr s l intervention de nettoyage ou de service remettez bien en place au remontage toute la visserie enlev e et v rifiez le bon fonctionnement des...

Страница 28: ...l ment 250 W pied par l ment Contr les int gr s Optionnel PANNEAU ARRI RE PANNEAU ARRI RE GRILLE GRILLE GRILLE PANNEAU ARRI RE THERMOSTAT OPTIONNEL THERMOSTAT OPTIONNEL PROTECTION CONTRE LES SURCHARGE...

Страница 29: ...DSH14 FL3 R DSH14 FL6 R DSH14 FL9 R DSH14 FL12 R DSH14 FL18 R DSH14 IC 1 DSH14 OC 1 DSH14 BL2 1 DSH14 BL3 1 DSH14 BL4 1 DSH14 BL5 1 DSH14 BL6 1 DSH14 BL8 1 DSH14 BL10 1 DSH14 BCS SHCC 07 14 Extension...

Страница 30: ...UTES LES AUTRES GARANTIES EXPLICITES OU IMPLICITES ET TOUTES LES GARANTIES IMPLICITES DE VALEUR MARCHANDE ET D AD QUATION POUR UNE FINALIT SP CIFIQUE QUI EXC DERAIENT LES DISPOSITIONS DE GARANTIE PR C...

Отзывы: