background image

11/10

Part No. 5200-2674-001

ECR 38636

LIMITED WARRANTY

All  products  manufactured  by  Marley  Engineered  Products  are  warranted  against  defects  in  workmanship  and  materials  for  one  year  from  date  of  installation,  except 
heating elements which are warranted against defects in workmanship and materials for five years from date of installation. This warranty does not apply to damage from
accident,  misuse,  or  alteration;  nor  where  the  connected  voltage  is  more  than  5%  above  the  nameplate  voltage;  nor  to  equipment  improperly  installed  or  wired  or 
maintained in violation of the product’s installation instructions. All claims for warranty work must be accompanied by proof of the date of installation.

The customer shall be responsible for all costs incurred in the removal or reinstallation of products, including labor costs, and shipping costs incurred to return products
to Marley Engineered Products Service Center. Within the limitations  of this warranty, inoperative units should be returned to the nearest Marley authorized service cen-
ter or the Marley Engineered Products Service Center, and we will repair or replace, at our option, at no charge to you with return freight paid by Marley. It is agreed that
such repair or replacement is the exclusive remedy available from Marley Engineered Products.

THE ABOVE WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED, AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE WHICH EXCEED THE AFORESAID EXPRESSED WARRANTIES ARE HEREBY DISCLAIMED AND EXCLUDED FROM
THIS  AGREEMENT.  MARLEY  ENGINEERED  PRODUCTS SHALL  NOT  BE  LIABLE  FOR  CONSEQUENTIAL  DAMAGES  ARISING  WITH  RESPECT  TO  THE 
PRODUCT, WHETHER BASED UPON NEGLIGENCE, TORT, STRICT LIABILITY, OR CONTRACT.

Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above exclusion or limitation may not apply to you. This warranty gives
you specific legal rights, and you may also have other rights which vary from state to state.

For the address of your nearest authorized service center, contact Marley Engineered Products in Bennettsville, SC, at 1-800-642-4328. Merchandise returned to the fac-
tory must be accompanied by a return authorization and service identification tag, both available from Marley Engineered Products. When requesting return authorization,
include all catalog numbers shown on the products.

470 Beauty Spot Rd. East
Bennettsville, SC  29512 USA

HOW TO OBTAIN WARRANTY SERVICE AND 
WARRANTY PARTS PLUS GENERAL INFORMATION

1. Warranty Service or Parts

1-800-642-4328

2. Purchase Replacement Parts

1-800-654-3545

3. General Product Information

www.marleymep.com

Note: When obtaining service always have the following:

1. Model number of the product
2. Date of manufacture
3. Part number or description

Содержание CSH05A

Страница 1: ...ing this heater 7 This heater is not for residential or household use CSH and DSH Convectors Installation Operation Maintenance Instructions Commercial Sill Height Convection Heaters Type CSH GENERAL...

Страница 2: ...ix with CSH05A 5 1 2 height heaters DSH05A 5 1 2 height heaters Model CSH05A DSH05A H 5 1 2 D 3 Table A Table A continued Amperage Catalog Length Total 208V 240V 277V Number L Watts Ft Watts 1 3 1 3 1...

Страница 3: ...ishings Away From Heater For effi cient and safe operation we recommend maintaining a min imum of 6 inches 152 mm clearance above and in front of the heater at all times See Clearances Chart for minim...

Страница 4: ...Minimum mounting heights above the floor shall be as follows Minimum Mounting Height Above Floor Watts Ft Heater Length Bottom Inlet Front Inlet 125 188 and 250 Watts Ft 1 3 4 0 376 500 625 and 750 3...

Страница 5: ...with mounting screws See Figure 2 Installation of Multiple Wall to Wall Units Note For ease of installation it is important that the sequence of operations indicated below be followed in order 1 Remo...

Страница 6: ...agram on control sections for connecting the wiring to the heaters Installation of Mullion to Mullion Units The back of the heater housing contains no mounting holes other than those at the ends and t...

Страница 7: ...s since these could damage the finish or discolor in use 2 A vacuum cleaner and or compressed air may be used to remove dust and lint that may have accumulated inside heater around element fins If hea...

Страница 8: ...8...

Страница 9: ...07A CSH14A Add suffix 1 for bottom inlet top outlet Add suffix 3 for bottom inlet front outlet Intended for the installation of components R Suffix on catalog number refers to accessories with 120 VAC...

Страница 10: ...Products THE ABOVE WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH EXCEED THE AFORESAID EXP...

Страница 11: ...o en el interruptor de desconexi n principal o panel de servicio 7 Este calefactor no es para uso residencial ni hogare o Calefactores de convecci n CSH y DSH Instrucciones de instalaci n operaci n y...

Страница 12: ...8125 125 1000 4 8 4 2 3 6 8188 8 188 1500 7 2 6 2 5 4 8250 250 2000 9 6 8 3 7 2 10125 125 1250 6 0 5 2 4 5 10188 10 188 1875 9 0 7 8 6 7 10250 250 2500 12 0 10 4 9 0 Prefijo con CSH05A calefactores c...

Страница 13: ...io 4 Antes de instalar o energizar el calefactor remueva y deseche el material de empaque de espuma colocado dentro del calefactor 5 No instale el calefactor contra superficies combustibles de tabla d...

Страница 14: ...portante seguir en orden la secuencia de operaciones indicada abajo 1 Remueva la cubierta delantera removiendo los tornillos de montaje Figura 2 2 Remueva la tapa precortada removible apropiada de cua...

Страница 15: ...aciones indicada abajo 1 1 Remueva todas las cubiertas delanteras de los calefactores removiendo los tornillos de montaje Figura 2 2 Consulte el diagrama de cableado para la entrada del alambre s de a...

Страница 16: ...bres a los calefactores Instalaci n de unidades de entreventana a entreventana miembro vertical intermedio en el marco de una ventana La parte trasera de la carcasa del calefactor no contiene orificio...

Страница 17: ...da ar las aletas 3 Despu s de limpiar y suministrar servicio de mantenimiento siempre reensamble colocando nuevamente cualquier herraje removido y revise las unidades para verificar que est n funcion...

Страница 18: ...Pie por elemento calefactor 250 W Pie por elemento calefactor Controles incorporados Opcional PANEL TRASERO PANEL TRASERO PANEL TRASERO REJILLA REJILLA REJILLA TERMOSTATO OPCIONAL TERMOSTATO OPCIONAL...

Страница 19: ...1 DSH14 BL4 1 DSH14 BL5 1 DSH14 BL6 1 DSH14 BL8 1 DSH14 BL10 1 DSH14 BCS SHCC 07 14 Adici n de longitud N N mero de cat logo CSH05A CSH07A CSH14A Agregue el sufijo 1 para entrada inferior por abajo sa...

Страница 20: ...ed Products LAS ANTERIORES GARANT AS REEMPLAZAN CUALQUIER OTRA GARANT A EXPRESA O IMPL CITA Y TODAS LAS GARANT AS IMPL CITAS DE MERCADE ABILIDAD Y ADECUADIBILIDAD PARA UN PROP SITO EN PARTICULAR QUE E...

Страница 21: ...diateur est bien d branch en amont l interrupteur g n ral ou au pan neau de service avant d intervenir pour installer ou d panner ce radiateur 7 Ce radiateur n est pas pour une utilisation r sidentiel...

Страница 22: ...25 1250 6 0 5 2 4 5 10188 10 188 1875 9 0 7 8 6 7 10250 250 2500 12 0 10 4 9 0 Pr fixe avec CSH05A radiateurs de 5 1 2 de haut CSH05A radiateurs de 5 1 2 de haut Mod les CSH05A DSH05A H 5 1 2 P 3 Tabl...

Страница 23: ...die 4 Enlevez de l int rieur du radiateur et mettez au rebut les mat riaux d emballage en mousse avant d installer le radiateur et de le mettre sous tension 5 N installez pas le radiateur contre des s...

Страница 24: ...t unique Remarque Pour faciliter l installation il est important que la s quence des op rations indiqu es ci apr s soit suivie dans l ordre 1 Enlevez le couvercle frontal en tant ses vis de fixation F...

Страница 25: ...quence des op rations indiqu es ci apr s soit suivie dans l ordre 1 Enlevez tous les couvercles frontaux des radiateurs en tant leurs vis de fixation Figure 2 2 R f rez vous au sch ma de c blage pour...

Страница 26: ...ils aux radiateurs Installation d unit de meneau meneau Le dos du carter de radiateur ne comporte pas de trous de montage autres que ceux dispos s aux extr mit s et de ce fait c est id al pour une ins...

Страница 27: ...yant les ailettes d l ment pour ne pas les abimer 3 Apr s l intervention de nettoyage ou de service remettez bien en place au remontage toute la visserie enlev e et v rifiez le bon fonctionnement des...

Страница 28: ...l ment 250 W pied par l ment Contr les int gr s Optionnel PANNEAU ARRI RE PANNEAU ARRI RE GRILLE GRILLE GRILLE PANNEAU ARRI RE THERMOSTAT OPTIONNEL THERMOSTAT OPTIONNEL PROTECTION CONTRE LES SURCHARGE...

Страница 29: ...DSH14 FL3 R DSH14 FL6 R DSH14 FL9 R DSH14 FL12 R DSH14 FL18 R DSH14 IC 1 DSH14 OC 1 DSH14 BL2 1 DSH14 BL3 1 DSH14 BL4 1 DSH14 BL5 1 DSH14 BL6 1 DSH14 BL8 1 DSH14 BL10 1 DSH14 BCS SHCC 07 14 Extension...

Страница 30: ...UTES LES AUTRES GARANTIES EXPLICITES OU IMPLICITES ET TOUTES LES GARANTIES IMPLICITES DE VALEUR MARCHANDE ET D AD QUATION POUR UNE FINALIT SP CIFIQUE QUI EXC DERAIENT LES DISPOSITIONS DE GARANTIE PR C...

Отзывы: