background image

Decorative Sill Height Convection Heaters 
(Type DSH)

WARNING

SAVE THESE INSTRUCTIONS

WHEN USING ELECTRICAL APPLIANCES, BASIC PRECAU-
TIONS SHOULD ALWAYS BE FOLLOWED TO REDUCE
THE RISK OF FIRE, ELECTRIC SHOCK, AND INJURY TO
PERSONS, INCLUDING THE FOLLOWING:

1. Read all instructions before installing or using the heater.

2. A heater has hot and arcing or sparking parts inside.  Do not

use in areas where gasoline or flammable liquids are used
or stored.  Do not use in corrosive environment or any area
where explosive materials are used or stored.

3. This heater is hot when in use.  To avoid burns, do not let

bare skin touch hot surfaces.  Keep combustible materials,
such as furniture, pillows, bedding, papers, clothes, and cur-
tains away from heater.

4. To  prevent  a  possible  fire,  do  not  block  air  intakes  or

exhaust in any manner.

5. Do not insert or allow foreign objects to enter any ventilation

or exhaust opening as this may cause an electric shock or
fire, or damage the heater.

6. Serious  injury  or  death  could  result  from  electric  shock.

Make sure electrical power supply circuit coming to heater
is disconnected at main disconnect or service panel before
installing or servicing this heater.

7. This heater is not for residential or household use.

CSH and DSH 

Convectors

Installation, Operation & Maintenance Instructions

Commercial Sill Height Convection Heaters 
(Type CSH)

!

GENERAL

This heater is designed to provide years of efficient, trouble free operation as a primary or supplementary heat source for comfort
heating in residential and commercial applications. CSH and DSH convector heaters must be thermostatically controlled for efficient,
safe operation.  A thermostat is not provided with this heater.  However, a single or double pole thermostat accessory is available
for installation into this heater at your place of purchase, or the heater may be connected to any suitable wall mounted thermostat
that will meet the electrical load requirements.  Installation or use of this product in any manner not described herein will void the
warranty and could result in injury, damage to property, or permanent damage to heater.

IMPORTANT INSTRUCTIONS

RECEIVING

Material when shipped was in good order and Marley
Engineered Products holds clear bill of lading, therefore any
concealed damage must be reported at once to the carrier for
inspection and settlement.

Note: It is advisable to store cartons in a central area to be
drawn upon as needed per room requirements.  If called for on
order, the cartons will have been tagged with proper room 
number.

Содержание CSH05A

Страница 1: ...ing this heater 7 This heater is not for residential or household use CSH and DSH Convectors Installation Operation Maintenance Instructions Commercial Sill Height Convection Heaters Type CSH GENERAL...

Страница 2: ...ix with CSH05A 5 1 2 height heaters DSH05A 5 1 2 height heaters Model CSH05A DSH05A H 5 1 2 D 3 Table A Table A continued Amperage Catalog Length Total 208V 240V 277V Number L Watts Ft Watts 1 3 1 3 1...

Страница 3: ...ishings Away From Heater For effi cient and safe operation we recommend maintaining a min imum of 6 inches 152 mm clearance above and in front of the heater at all times See Clearances Chart for minim...

Страница 4: ...Minimum mounting heights above the floor shall be as follows Minimum Mounting Height Above Floor Watts Ft Heater Length Bottom Inlet Front Inlet 125 188 and 250 Watts Ft 1 3 4 0 376 500 625 and 750 3...

Страница 5: ...with mounting screws See Figure 2 Installation of Multiple Wall to Wall Units Note For ease of installation it is important that the sequence of operations indicated below be followed in order 1 Remo...

Страница 6: ...agram on control sections for connecting the wiring to the heaters Installation of Mullion to Mullion Units The back of the heater housing contains no mounting holes other than those at the ends and t...

Страница 7: ...s since these could damage the finish or discolor in use 2 A vacuum cleaner and or compressed air may be used to remove dust and lint that may have accumulated inside heater around element fins If hea...

Страница 8: ...8...

Страница 9: ...07A CSH14A Add suffix 1 for bottom inlet top outlet Add suffix 3 for bottom inlet front outlet Intended for the installation of components R Suffix on catalog number refers to accessories with 120 VAC...

Страница 10: ...Products THE ABOVE WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH EXCEED THE AFORESAID EXP...

Страница 11: ...o en el interruptor de desconexi n principal o panel de servicio 7 Este calefactor no es para uso residencial ni hogare o Calefactores de convecci n CSH y DSH Instrucciones de instalaci n operaci n y...

Страница 12: ...8125 125 1000 4 8 4 2 3 6 8188 8 188 1500 7 2 6 2 5 4 8250 250 2000 9 6 8 3 7 2 10125 125 1250 6 0 5 2 4 5 10188 10 188 1875 9 0 7 8 6 7 10250 250 2500 12 0 10 4 9 0 Prefijo con CSH05A calefactores c...

Страница 13: ...io 4 Antes de instalar o energizar el calefactor remueva y deseche el material de empaque de espuma colocado dentro del calefactor 5 No instale el calefactor contra superficies combustibles de tabla d...

Страница 14: ...portante seguir en orden la secuencia de operaciones indicada abajo 1 Remueva la cubierta delantera removiendo los tornillos de montaje Figura 2 2 Remueva la tapa precortada removible apropiada de cua...

Страница 15: ...aciones indicada abajo 1 1 Remueva todas las cubiertas delanteras de los calefactores removiendo los tornillos de montaje Figura 2 2 Consulte el diagrama de cableado para la entrada del alambre s de a...

Страница 16: ...bres a los calefactores Instalaci n de unidades de entreventana a entreventana miembro vertical intermedio en el marco de una ventana La parte trasera de la carcasa del calefactor no contiene orificio...

Страница 17: ...da ar las aletas 3 Despu s de limpiar y suministrar servicio de mantenimiento siempre reensamble colocando nuevamente cualquier herraje removido y revise las unidades para verificar que est n funcion...

Страница 18: ...Pie por elemento calefactor 250 W Pie por elemento calefactor Controles incorporados Opcional PANEL TRASERO PANEL TRASERO PANEL TRASERO REJILLA REJILLA REJILLA TERMOSTATO OPCIONAL TERMOSTATO OPCIONAL...

Страница 19: ...1 DSH14 BL4 1 DSH14 BL5 1 DSH14 BL6 1 DSH14 BL8 1 DSH14 BL10 1 DSH14 BCS SHCC 07 14 Adici n de longitud N N mero de cat logo CSH05A CSH07A CSH14A Agregue el sufijo 1 para entrada inferior por abajo sa...

Страница 20: ...ed Products LAS ANTERIORES GARANT AS REEMPLAZAN CUALQUIER OTRA GARANT A EXPRESA O IMPL CITA Y TODAS LAS GARANT AS IMPL CITAS DE MERCADE ABILIDAD Y ADECUADIBILIDAD PARA UN PROP SITO EN PARTICULAR QUE E...

Страница 21: ...diateur est bien d branch en amont l interrupteur g n ral ou au pan neau de service avant d intervenir pour installer ou d panner ce radiateur 7 Ce radiateur n est pas pour une utilisation r sidentiel...

Страница 22: ...25 1250 6 0 5 2 4 5 10188 10 188 1875 9 0 7 8 6 7 10250 250 2500 12 0 10 4 9 0 Pr fixe avec CSH05A radiateurs de 5 1 2 de haut CSH05A radiateurs de 5 1 2 de haut Mod les CSH05A DSH05A H 5 1 2 P 3 Tabl...

Страница 23: ...die 4 Enlevez de l int rieur du radiateur et mettez au rebut les mat riaux d emballage en mousse avant d installer le radiateur et de le mettre sous tension 5 N installez pas le radiateur contre des s...

Страница 24: ...t unique Remarque Pour faciliter l installation il est important que la s quence des op rations indiqu es ci apr s soit suivie dans l ordre 1 Enlevez le couvercle frontal en tant ses vis de fixation F...

Страница 25: ...quence des op rations indiqu es ci apr s soit suivie dans l ordre 1 Enlevez tous les couvercles frontaux des radiateurs en tant leurs vis de fixation Figure 2 2 R f rez vous au sch ma de c blage pour...

Страница 26: ...ils aux radiateurs Installation d unit de meneau meneau Le dos du carter de radiateur ne comporte pas de trous de montage autres que ceux dispos s aux extr mit s et de ce fait c est id al pour une ins...

Страница 27: ...yant les ailettes d l ment pour ne pas les abimer 3 Apr s l intervention de nettoyage ou de service remettez bien en place au remontage toute la visserie enlev e et v rifiez le bon fonctionnement des...

Страница 28: ...l ment 250 W pied par l ment Contr les int gr s Optionnel PANNEAU ARRI RE PANNEAU ARRI RE GRILLE GRILLE GRILLE PANNEAU ARRI RE THERMOSTAT OPTIONNEL THERMOSTAT OPTIONNEL PROTECTION CONTRE LES SURCHARGE...

Страница 29: ...DSH14 FL3 R DSH14 FL6 R DSH14 FL9 R DSH14 FL12 R DSH14 FL18 R DSH14 IC 1 DSH14 OC 1 DSH14 BL2 1 DSH14 BL3 1 DSH14 BL4 1 DSH14 BL5 1 DSH14 BL6 1 DSH14 BL8 1 DSH14 BL10 1 DSH14 BCS SHCC 07 14 Extension...

Страница 30: ...UTES LES AUTRES GARANTIES EXPLICITES OU IMPLICITES ET TOUTES LES GARANTIES IMPLICITES DE VALEUR MARCHANDE ET D AD QUATION POUR UNE FINALIT SP CIFIQUE QUI EXC DERAIENT LES DISPOSITIONS DE GARANTIE PR C...

Отзывы: