Appendix F: Pump Cycle Counter
Revision 7 - August, 2007
Pump Cycle Counter Operation/Installation
When a pneumatically operated pump such as the
QED
AutoPump® has filled,
it triggers itself “On”. This allows air to flow to the pump until a certain volume
of fluid has discharged. The air stops; the pump fills; then the cycle continues
to repeat.
A PCC mounted between a filter/regulator and a pump senses air flow to the
pump. In a piston-like action, the internally located magnet shuttle moves
forward (in the direction of air flow) during the “On” pulse and returns to a
seated position in the “Off” period.
(See Figure 35)
The digital display senses the completion of this “to-and-from” movement and
records the cycle, increasing the number one digit that is shown in the clear
plastic display.
This process repeats itself for each pump cycle.
Note:
The PCC will not function properly beyond certain distance limits from
the pump, or, above or below optimum air line diameters. Safe limits are
as follows:
AP-4: 250 ft. maximum with 1/4 inch or 3/8 inch ID air hose.
AP-3: 150 ft. maximum with 1/4 inch or 3/8 inch ID air hose.
AP-2: 75 ft. maximum with 1/4 inch or 3/8 inch ID air hose.
Contact
QED
for advice.
Digital Display
The digital display has the following features:
• A six digit counter that counts from 0 - 999,999 before resetting itself.
• A clear viewing lens that is water-and-impact resistant.
•
Optional
: Switch for remote electronic readout available upon
request.
(See Figure 37)
Содержание AutoPump AP-2
Страница 15: ...Page 7 AP 2 Manual Revision 7 August 2007 Figure 1 How it Works Chapter 2 Overview 601345...
Страница 17: ...Page 9 AP 2 Manual Revision 7 August 2007 Figure 2 Overview of the AutoPump System Chapter 2 Overview...
Страница 22: ...QED Environmental Systems AP 2 Manual Page 14 Figure 3 Long and Short Bottom Loading AP 2 BL...
Страница 23: ...Page 15 AP 2 Manual Revision 7 August 2007 Chapter 3 Equipment Figure 4 Long and Short Top Loading AP 2 TL...
Страница 32: ...QED Environmental Systems AP 2 Manual Page 24 Figure 7 Locking Quick Connects...
Страница 34: ...QED Environmental Systems AP 2 Manual Page 26 Figure 9 AP 2 Assembly Well Cap with Holes...
Страница 38: ...QED Environmental Systems AP 2 Manual Page 30 Figure 11 Examples of Well Caps...
Страница 40: ...QED Environmental Systems AP 2 Manual Page 32 Figure 12 Hose Bundling Part 1 of 2...
Страница 53: ...Page 45 AP 2 Manual Revision 7 August 2007 Chapter 6 Maintenance Figure 14 Removing AP 2 Pump Casing...
Страница 54: ...QED Environmental Systems AP 2 Manual Page 46 Figure 15 Exploded view of a Long Top Loading AutoPump AP 2...
Страница 56: ...QED Environmental Systems AP 2 Manual Page 48 Figure 17 Exploded View of a Long Bottom Loading AutoPump AP 2...
Страница 58: ...QED Environmental Systems AP 2 Manual Page 50 Figure 19 Exploded View of AP 2 Lever Assembly...
Страница 82: ...QED Environmental Systems AP 2 Manual Page 74 Figure 29 Conversion From Top Loading to Bottom Loading AutoPump...
Страница 102: ...QED Environmental Systems AP 2 Manual Page 94 Figure 37 Pump Cycle Counter with Magnetic Reed Switch...
Страница 109: ...Page 101 AP 2 Manual Revision 7 August 2007 Log Notes...
Страница 110: ...Clean Environment Equipment AP 2 Manual Page 102...
Страница 111: ...Page 103 AP 2 Manual Revision 7 August 2007 Log Notes...