PSI System Controls and Diagnostics
A500 User Manual
A500_UM_090115 Page 39 of 61
12
Controls and Indicators
12.1 Front panel controls
None.
12.2 Rear panel controls
RESET
ADDRESS SELECTOR SWITCHES (3)
Figure 20. Portion of the rear panel showing controls
12.2.1 Reset button
Momentary push-button to reset the cell controller board FPGA and DSP. The A500 will reboot
when the switch is pressed.
12.2.2 IP address selector switches
Three ten-position rotary switch setting the last three digits of the IP address. Digits indicate the
last eight bits of the full IP address. Allowed values for IP addresses are 001 to 254. The
switches are read at boot up only.
Two special codes are available outside the normal IP address range, which cause special bootup
behaviour:
888
The A500 will go through the POST, but then halts in the boot state. The IP
address is forced to 192.168.100.100.
999
The A500 will go through the POST, and launch the installed firmware. The IP
address is forced to 192.168.100.100.