5
Puretec Radfire RI-HF Series
Copyright © Puretec Pty Ltd 2022
12. Pressure must be relieved from the system prior to any maintenance, to prevent dam-
age to the equipment or personal injury. De-pressurize and drain the UV reactor prior to
maintenance.
WARNING:
THE UV LIGHT GIVEN OFF BY THIS UNIT CAN
CAUSE SERIOUS BURNS TO UNPROTECTED EYES AND
SKIN. NEVER LOOK DIRECTLY AT AN ILLUMINATED UV
LAMP. WHEN PERFORMING ANY WORK ON THE UV DIS-
INFECTION SYSTEM ALWAYS UNPLUG THE UNIT FIRST.
NEVER OPERATE UV SYSTEM WHILE THE UV LAMP IS
OUTSIDE OF THE UV CHAMBER.
System Overview
Each UV system is designed to treat water at specified flow rates as outlined in the
specification sheet. All Puretec Series units are provided with two main component parts,
specifically the ultraviolet reactor chamber and the main controller.
Reactor Chamber
The reactor chamber is manufactured from stainless steel 316L and houses the ultraviolet
lamp and quartz sleeve. The lamps used in the Puretec RI-HF models are of a special high
intensity, high output and Amalgam germicidal type. The chamber is designed to mount
horizontally and should be secured to a suitable support. A vertical installation may be
possible but Puretec should first be consulted.
Control Panel
The main controller is made of powder coated steel. The controller is connected to the
chamber via 3.5 meters of cable to allow for application flexibility.
Standard Electronics
1. All Puretec control boxes are equipped with an on/off switch. When the main power to
the system is turned on, the lamp will turn on directly.
2. A separate user accessible fuse or circuit breaker is also provided as protection for the
electronics.
3. A seven segment LED display monitors the remaining number of useful hours of the UV
lamp (Time Elapse Meter) and the days the UV system has been in operation.
4. An audio-visual “Lamp Life Over” and “Lamp Failure” indicator.
5. The Puretec RI-HF Series purchased with the UV Intensity meter option includes a built in
UV Intensity meter along with sensor.
System Overview
Содержание RI-HF19