UV Intensity Sensor Calibration Resetting
In case of a new installation or when the lamp is replaced with a new one, it is important to
reset the sensor calibration settings. This must also be performed in case a new sensor is
being fitted to the system.
Follow the procedure as per the instructions in the Recalibrating The UV Sensor section.
Maintenance
UV Lamp
The RI-HF UV lamps are mounted inside the UV reactor. Each UV Lamp is housed within its
own protective quartz sleeve, which protects it from water flow. The sleeves are supported on
both sides of the reactor by the end plates. The entire lamp and then quartz sleeve can be
removed for service.
The germicidal UV lamp is a low pressure, high intensity and amalgam type lamp, with
preheated starting to promote lamp life.
The frequency of UV lamp replacement will depend on various factors such as:
•
Water temperature, max operating temperature = 45°C
•
Frequency of switching lamps ON and OFF
•
Total operating time of the lamps. Maximum operating hours is 12,000 hours
•
NOTE:
DO NOT CYCLE LAMPS ON/OFF MORE THAN THREE (3) TIMES PER 24-HOUR PERIOD.
CYCLING OF LAMPS ON/OFF MORE THAN 3 TIMES IN A 24-HOUR PERIOD MAY RESULT IN
PREMATURE LAMP FAILURE AND VOID OF WARRANTY.
Use only quality replacement parts from Puretec. Using any non-genuine lamps, quartz,
O-rings or spares in the UV system can affect the performance of the system and void the
warranty.