13
INTAC
®
Terminal Board Connections
* Factory Option
-
This is a fixed value and can not be field modified. Factory set option only.
7
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
7
6
5
4
3
2
1
6
5
4
3
2
1
1
2
3
4
5
6
7
1
2
3
4
5
6
1
2
3
4
5
6
7
1
2
3
4
5
6
J5
J1
J6
J7
J9
J4
J8
J2
J3
Low Level Probe
Refill Level Probe
High Level Probe
Tank Ground
Humidifier
Tank
1
2
3
Gray
Violet
Blue
TANK FILL VALVE * Enabled when menu 705 is set to "TRI-PROBE
TANK DRAIN VALVE *
Factory Option Enabled in menu 706
Yellow
Black
White
Black
24
VD
C
(+)
UNRE
G
U
LATE
D
24
VD
C
(-
) COM
MO
N
24
VD
C
(+)
UNRE
G
U
LATE
D
24
VD
C
(+)
UNRE
G
U
LATE
D
DC POWER SUPPLY
FOR HUMIDITY
AND TEMPERATURE
SENSORS
A-
B+
REF. GROUND
CURRENT (+)
COMMON(-)
OUTER BOARD
INNER BOARD
VOLTAGE (+)
COMMON (-)
OV
E
R-
TE
MPE
R
A
TUR
E
SWIT
CH
(S)
(s
wit
ch
op
en
s o
n
te
mp.
ris
e, 250
°F
)
AIR
FLO
W S
W
IT
CH
(s
wit
ch
cl
os
es
w
ith a
ir flow)
ON/
O
FF
HI
G
H
-LIM
IT H
UMID
IST
A
T
(s
wit
ch
op
en
s o
n
RH
ri
se)
SAFETY CIRCUIT
Yellow (+)
Red (-)
VOLTAGE (+)
CURRENT (+)
COMMON (-)
CURRENT (+)
COMMON (-)
Green
LO
W WATER
FL
OA
T S
W
IT
C
H *
(switc
h
opens
w
ith l
ow wat
er
)
In
pu
t is
ac
tive o
nly
w
hen m
enu
7
05
is set
to "FL
OA
T"
BACK SIDE OF THE
INTAC
CONTROLLER MOUNTED
ON THE PANEL DOOR
®
1 AMP @
24
V
AC
(c
onta
ct
closes on
a
larm
)
H
IGH/
LOW
HUMI
DI
TY AL
ARM
C
O
N
TACT
S
D
IS
A
B
LE
SWIT
CH
(a
closed conta
ct
di
sab
le
s
the
humidi
fier
)
D
ED
IC
A
TED
INPU
T/
PANE
L
LOCK-O
UT
(a
closed conta
ct
locks t
he
p
an
el
)
White
Green
Violet
Gold
No Color
Yellow
Blue
Red
Silver
24
VAC
COM
M
O
N
24
VA
C
HO
T
PAN
E
L
G
RO
UN
D
PI
LOT
R
E
LAY
- 2
4V
A
C
(p
lu
g in
cube r
el
ay)
+ 5 VDC
TRI
G
G
ER
24
VAC
COM
M
O
N
H
EA
TER
#
4
/ B
UR
N
ER #
3
H
EA
TER
#
3
/ B
UR
N
ER #
2
H
EA
TER
#
2
/ B
UR
N
ER #
1
TANK WATER TEMP THERMOCOUPLE *
Factory Option Enabled in menu 703 and Configured in Menu 503
HEATER #1 / Blower
TRI-PROBE - Standard water units only *
See Specifications page for wiring limitations
Input is active when menu 705 is set to
"TRI-PROBE"
INNER
BOARD
OUTER
BOARD
7
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
7
6
5
4
3
2
1
6
5
4
3
2
1
1
2
3
4
5
6
7
1
2
3
4
5
6
1
2
3
4
5
6
7
1
2
3
4
5
6
Tank Ground
Humidifier
Tank
1
2
3
24
VD
C
(+)
UNRE
G
U
LATE
D
24
VD
C
(-
) COM
MO
N
24
VD
C
(+)
UNRE
G
U
LATE
D
24
VD
C
(+)
UNRE
G
U
LATE
D
MODBUS
RS485 COM
CONNECTIONS
VOLTAGE (+)
CURRENT (+)
OV
E
R-
TE
MPE
R
A
TUR
E
SWIT
CH
(S)
(s
wit
ch
op
en
s o
n
te
mp.
ris
e, 250
°F
)
AIR
FLO
W S
W
IT
CH
(s
wit
ch
cl
os
es
w
ith a
ir flow)
ON/
O
FF
HI
G
H
-LIM
IT H
UMID
IST
A
T
(s
wit
ch
op
en
s o
n
RH
ri
se)
SAFETY CIRCUIT
®
1 AMP @
24
V
AC
(c
onta
ct
closes on
a
larm
)
H
IGH/
LOW
HUMI
DI
TY AL
ARM
C
O
N
TACT
S
White
Green
Violet
Gold
No Color
Yellow
Blue
Red
Silver
24
VA
C
HO
T
PAN
E
L
G
RO
UN
D
ON/
O
FF
HUMI
DI
STA
T *
(s
wit
ch
op
en
s o
n
RH
ri
se)
In
pu
t is
ac
tive wh
en
me
nu 701 is
s
et
to
"O
N
/OF
F"
PI
LOT
R
E
LAY
- 2
4V
A
C
(p
lu
g in
cube r
el
ay)
+ 5 VDC
TRI
G
G
ER
24
VAC
COM
M
O
N
H
EA
TER
#
4
/ B
UR
N
ER #
3
H
EA
TER
#
3
/ B
UR
N
ER #
2
H
EA
TER
#
2
/ B
UR
N
ER #
1
Use shielded cable (Beldon #9842 minimum)
ISOLATED
CONTROL INPUT OR HUMIDITY/SENSOR INPUT *
Input is active except when Control Type is ON/OFF and is configured in menus 502 and 504 thru 506
MODULATING HIGH LIMIT RELATIVE HUMIDITY INPUT *
Factory Option Enabled in menu 707 and Configured in Menus 508 thru 510
Input is functional only when menu 502 is set to "Transmitter"
CURRENT OUTDOOR AIR TEMP SENSOR INPUT *
Factory Option Enabled in menu 704 and Configured in Menus 511 thru 516
Input is functional only when menu 502 is set to "Transmitter"
ANALOG PROCESS OUTPUT *
Output is active when menu 701 is set to Gas or Steam and is Configured in menus 517 thru 519
Содержание INTAC
Страница 29: ...27 Notes Action Performed Date By...
Страница 30: ...28...
Страница 31: ...29...
Страница 32: ...30 141 Jonathan Blvd North Chaska MN 55318 Tel 952 368 9335 Fax 952 368 9338 www purehumidifier com...