DRIVESYSTEMS
REDUCER MOUNTING
FOOTED & FLANGE MOUNT GEAR UNITS
RETAIN FOR FUTURE USE
U10500 - 1 of 2
1. Foot-mounted reducers
When installing the foot-mounted gear unit, observe the
fl atness specifi cations and bolt tightening torque guidelines
provided in U10060 and make sure the mating mounting
surface and reducer feet are clean and free of debris. Use
of shims under the feet of the gear unit may be required in
order to align the output shaft to the driven equipment.
Make sure that all feet are supported so that the housing
will not distort when it is bolted down. Improper shimming
will cause mis-alignment and may reduce the life of the gear
unit or cause component failure. Dowel pins may be fi eld-
installed to help prevent misalignment and ensure proper
realignment if removed for service.
IMPORTANT NOTE
Gear units may be subjected to radial loads or side pull,
caused by external chain drives or belt drives. In these
instances it is recommended that the mounting base be
designed with a slide-plate adjustment to accommodate
extra slack in the chain or the belt after the feet are
loosened. When using an external chain or belt drive,
make sure the reducer is sized so that the shaft and
bearings have adequate capacity.
2. Flange-mounted reducers (with B5 fl ange)
When using the B5 fl ange to mount the gear unit, the bulk
head plate must be engineered to minimize buckling distor-
tions and support the cantilevered weight of the gear reduc-
er or gearmotor. On the B5 mounting fl ange NORD provides
a pilot register or and the fl ange pilot tolerance as listed per
Table 1. When the mating hole is designed with the proper
fi t, the fl ange pilot tenon provides a means of accurately po-
sitioning the reducer while the hold-down bolts are properly
secured; once the reducer is secured, the tenon helps prevent
movement of the reducer and it helps locate the center of
the reducer output shaft.
Table : Flange Pilot Tolerance
Above
ø (in)
To &
Including
ø (in)
Tolerance
(in)
ISO 286-2
Fit Class
1.969
3.150
+0.0005 / -0.0003
j6
3.150
4.724
+0.0005 / -0.0004
j6
4.724
7.087
+0.0006 / -0.0004
j6
7.087
9.055
+0.0000 / -0.0005
h6
9.055
9.843
+0.0000 / -0.0011
h6
9.843
12.402
+0.0000 / -0.0013
h6
12.402
15.748
+0.0000 / -0.0014
h6
15.748
19.685
+0.0000 / -0.0016
h6
Above
ø (mm)
To &
Including
ø (mm)
Tolerance
(mm)
ISO 286-2
Fit Class
50
80
+0.012 / -0.007
j6
80
120
+0.013 / -0.009
j6
120
180
+0.014 / -0.011
j6
180
230
+0.000 / -0.013
h6
230
250
+0.000 / -0.029
h6
250
315
+0.000 / -0.032
h6
315
400
+0.000 / -0.036
h6
400
500
+0.000 / -0.040
h6
When installing the fl ange mounted gear unit, observe the
fl atness specifi cations and bolt tightening torque guidelines
provided in U10060. Make sure the mating mounting surface
and reducer fl ange are clean and free of debris. Use a straight
edge or parallel bar to check for high spots on the mating
mounting surface and remove any raised material around the
mounting holes.
Set the gear unit into place and tighten the bolts until they
are snug. Before fi nal bolt-tightening check for any mate-
rial gaps between the mating surfaces and if shimming is re-
quired, use “U” shaped shims at least 2 times the width of the
bolt. Avoid over shimming a very irregular surface as this will
make it very diffi cult to achieve proper alignment.
IMPORTANT NOTE
For heavy shock applications, it is advisable to fi eld-in-
stall dowel pins through the mounting fl ange connec-
tion (in addition to the mounting bolts). This will help
control fl ange movement or fl ange rotation and relieve
the mounting bolts from this additional stress.
www.nord.com/docs
06.09.09
NORD Gear Corporation
Toll Free in the United States: 888.314.6673
NORD Gear Limited
Toll Free in Canada: 800.668.4378
Содержание Pulsalube 8 GS Ultra
Страница 8: ......
Страница 18: ......
Страница 20: ......
Страница 36: ......
Страница 38: ......
Страница 42: ......
Страница 48: ......
Страница 50: ......
Страница 53: ......
Страница 54: ......
Страница 55: ......
Страница 56: ......
Страница 61: ......
Страница 62: ......
Страница 64: ......
Страница 86: ......
Страница 87: ......
Страница 88: ......
Страница 89: ...XVJDEH LVVXH RNXPHQW GRFXPHQW 20 6 XV ODWW VKHHW 6SDUH SDUWV 6SDUH SDUWV OLVW 6HFWLRQDO GUDZLQJ DQG SDUWV OLVW...
Страница 90: ......
Страница 93: ......
Страница 94: ......
Страница 96: ......
Страница 98: ......
Страница 100: ......
Страница 110: ......
Страница 113: ......
Страница 114: ......
Страница 116: ......
Страница 118: ......
Страница 122: ......
Страница 126: ......