OPTALIGN smart RS5 BT handbook
140
10. Repeat steps 8 and 9 to take measurements in at least three positions over at
least 70° of rotation. (Taking more position measurements improves the reliability
of results.)
11. When enough measurement points over at least 70° rotation have been taken,
press
q
then use
f
/
g
to highlight the context menu item ‘Stop’.
Confirm selection by pressing
e
to stop measurement.
7 .2 .5 Evaluation and alignment
Since offset does not affect the performance of cardan shafts, only angularity is
displayed for correction.
1. Press
k
to view alignment results.
Alternatively, stop
measurement by pressing
q
followed by
3
.
Содержание OPTALIGN smart RS5 BT
Страница 10: ...OPTALIGN smart RS5 BT handbook 10 Page intentionally left blank ...
Страница 16: ...OPTALIGN smart RS5 BT handbook 16 This page intentionally left blank ...
Страница 28: ...OPTALIGN smart RS5 BT handbook 28 Page intentionally left blank ...
Страница 38: ...OPTALIGN smart RS5 BT handbook 38 This page intentionally left blank ...
Страница 112: ...OPTALIGN smart RS5 BT handbook 112 This page intentionally left blank ...
Страница 174: ...OPTALIGN smart RS5 BT handbook 174 This page intentionally left blank ...
Страница 194: ...OPTALIGN smart RS5 BT handbook 194 This page intentionally left blank ...