14
EDDYSENSOR Operating Manual
• Press the Gain switch for approx. 1 second and release to go into the
high pass setting when the display shows
H.P
• The display then shows the current HP setting e.g. 1.1 and the bar of
unlit green LEDs represents the scale of the HP filter setting selected
(see diagrams below)
• Press to increase the value or – to decrease the HP setting
• After several seconds if the switch has not been touched, the display
briefly shows
L.P.
and then returns to the original gain mode.
The filter settings, like the gain, are permanently stored after being set up.
• Press the Gain switch for approx. 1 second and release to go into the
high pass setting when the display shows
H.P
• Press the Gain switch for a further second and release to go into the low
pass setting when the display shows
L.P.
• The display then shows the current LP setting e.g. 1.1., and the bar of
lighted red LEDs represents the scale of the LP filter setting selected
(see diagrams below)
• Press to increase the value or – to decrease the LP setting
• After several seconds if the switch has not been touched, the display
returns to the original gain mode
The filter settings, like the gain, are permanently stored after being set up.
Low pass filter setting
for F1 and F2
Press +/– to
increase/
decrease the
value
Press +/– to
increase/
decrease the
value
High pass filter setting
for F1 and F2
Press +/– to
increase/
decrease the
value
Press +/– to
increase/
decrease the
value
Unlit green
LEDs