24
Instructions for installation
REMINDERS FOR THE INSTALLER
The manufacturer will not be liable for any damage or
injury resulting from failure to observe the following
rules.
•
Read this manual carefully. It provides important
information for safe installation, use and
maintenance of the appliance.
•
Installation, conversion to a different type of gas
and appliance maintenance must be carried out by
qualified technicians authorized by the manufacturer,
in compliance with current safety standards and the
instructions given in this manual.
•
Identify the specific appliance model. The model
number is detailed on the packaging and on the
appliance data plate.
•
The appliance must be installed in a well-ventilated
room.
•
Do not obstruct any air vents or drains present on
the appliance.
•
Do not tamper with appliance components.
6. REFERENCE STANDARDS AND LAWS
Install the appliance in compliance with current safety
regulations.
Install the appliance in compliance with current
regulations.
7. HANDLING
The packaging is marked with warning symbols that
indicate the precautions to be taken when handling the
appliance to avoid damage.The appliance must only be
handledusing suitable equipment. If lifting equipment is
used, such as forklift trucks or similar, make sure that the
appliance is in a stable position.
8. UNPACKING
Check the state of the packaging and in the event of
damage, ask the delivery person to inspect the goods.
•
Remove the packaging.
•
Remove the protective film from the exterior and
interior panels. Use a suitable solvent to remove any
residual adhesive from the panels.
9. POSITIONING
•
The overall dimensions of the appliance and the
position of connections are given on the installation
diagram at the start of this manual.
•
The appliance can be installed singly or in
combination with other appliances in the same
product range.
•
The appliance is not suitable for integrated installation.
•
Position the appliance at least 10 cm from adjacent
walls. This distance can be reduced in the presence
of non-combustible walls or heat-insulated walls.
•
Level the appliance by means of the height-
adjustable feet.
APPLIANCE ASSEMBLY WITH BASE
Follow the instructions provided with the type of support
utilized.
JOINING APPLIANCES TOGETHER IN LINE
•
Place the appliances side by side and adjust the
tops to the same height.
•
Unite the appliances using the special unionjoint-
coverings supplied upon request
10. FUMES EXHAUST SYSTEM
Provide a fumes exhaust system based on the “Type”
of appliance.The “Type” is stated on the appliance
dataplate.
APPLIANCE TYPE “A1”
•
Position the “A1” type appliance below an extractor
hood to ensure smoke and fumes generated by
cooking are removed.
APPLIANCE TYPE “B21”
•
Position the “B21” type appliance below an extractor
hood.
APPLIANCE TYPE “B11”
Fit the “B11” type appliance with a suitable flue, available
from the appliance manufacturer. Follow the assembly
in-structions provided with the flue.
Connect the flue to a 150/155 mm diameter hose, heat
resistant to 300°C.
Vent to the outside or into an efficient flue. The hose
length must not exceed 3 metres.
11. CONNECTIONS
The position and dimensions of connections are given in
the installation diagram at the start of this manual.
CONNECTION TO THE GAS SUPPLY
Check the compatibility of the gas supply. Check the
details given on the decals on the packing and on the
appliance. If necessary, convert the appliance to the
type of gas utilized. Follow the instructions in the next
paragraph “Conversion to a different type of gas”.
On top appliances a rear connection is also available.
Remove the plug present and screw it tightly onto the
front connector.
•
A rapid-action gas shut-off valve must be fitted
upstream of the appliance in an easily accessible
position.
•
Do not use connection pipes having a diameter
smaller than that of the appliance’s gas connector.
•
Once the appliance has been installed, check for
leaks at the connection points.
12 CONVERSION TO A DIFFERENT TYPE OF GAS
Table T1 specifies, for each country:
•
which gas can be used for the appliance.
•
the nozzles and settings foreach gas that can be
used.For nozzles, the number indicated in table T1 is
also stamped on the nozzle body.
To convert the appliance to the local gas type, follow the
instructions given in atable T1 and carry out the steps
below:
•
Replace the main burner nozzle ( UM ).
•
Adjust the main burner’s air regulator to distance A.
•
Replace the pilot burner nozzle ( UP ).
•
Adjust the pilot burner air flow ( if necessary ).
•
Replace the gas valve minimum nozzle ( Um ).