enclosure
Usage
enclosure [-a <action>] -v
enclosure -a mod -s <list of settings>
enclosure -a locate [-t <FRU type> -f <FRU id>]
Summary
The enclosure command provides status and information about the various components of the enclosure unit. It
is also used to set thresholds for temperature and polling. In addition when using the -v option all VPD (Vendor
Provided Data) will be displayed.
Options
-a <action>
Which action to perform.
list
(Default) Displays information and status of the enclosure.
mod
Allows the user to modify settings when coupled with the -s switch.
locate
Allows the user to locate an enclosure by flashing LEDs
-e <encl id>
Enclosure ID. The default value is 1 if unspecified.
For list action, the default is for all enclosures if unspecified.
-i <sensor id>
IOM Sensor ID. For controller temperature warning (1..6) and critical
threshold. If unsepecified, only the IOM sensor 1,4 will be set, the IOM
sensor 2,3,5,6 will not changed.
-s “<option>=<value>”
Used to specify which Enclosure settings to change.
tempwarning=
(47 - 51) Temperature, displayed in Celsius, that the SEP will consider as
a warning threshold.
tempcritical=
(57 - 61) Temperature, in Celsius, that the SEP will consider as a critical
threshold.
158
Promise
Technology
VTrak D5000 Series Product Manual
Содержание VTrak D5000 Series
Страница 16: ...Front view of VTrak D5600 Drive carriers Enclosure Power and Status LEDs 7 Promise Technology Introduction ...
Страница 170: ...Examples event event v event c 200 event a list i 852 c 200 161 Promise Technology Managing with CLI ...
Страница 218: ...Examples spare spare a add p 14 t g spare a del i 0 209 Promise Technology Managing with CLI ...
Страница 233: ...Examples ups v ups a mod s ups1 192 168 1 1 rtr 5 224 Promise Technology VTrak D5000 Series Product Manual ...
Страница 245: ...236 Promise Technology VTrak D5000 Series Product Manual ...