background image

Beta Draft Confidential

 iv

Basic Series Network Thermostat Configuration Guide, Release 3.0

Part No. 600-01000-201, Rev. 1

Software License Agreement

DISCLAIMER OF 
WARRANTIES 
AND 
LIMITATION ON 
LIABILITY

No Warranties

. TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THE 

SOFTWARE IS PROVIDED "AS IS" AND PROLIPHIX AND ITS SUPPLIERS DISCLAIM ALL 
WARRANTIES, EITHER EXPRESSED OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, 
IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR 
PURPOSE.

No Liability for Consequential Damages

. TO THE MAXIMUM EXTENT PERMITTED BY 

APPLICABLE LAW, IN NO EVENT SHALL PROLIPHIX OR ITS SUPPLIERS BE LIABLE FOR 
ANY SPECIAL, INCIDENTAL, INDIRECT, OR CONSEQUENTIAL DAMAGES WHATSOEVER 
(INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS PROFITS, 
BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION, OR ANY OTHER 
PECUNIARY LOSS) ARISING OUT OF THE USE OF OR INABILITY TO USE THE 
SOFTWARE,EVEN IF PROLIPHIX HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH 
DAMAGES.

OTHER 

If any provision of this LICENSE is inconsistent with, or cannot be fully enforced under, the law, such 
provision will be construed as limited to the extent necessary to be consistent with and fully enforceable 
under the law. This LICENSE is the final, complete and exclusive agreement between the parties relating 
to the subject matter hereof, and supersedes all prior or contemporaneous understandings and agreements 
relating to such subject matter, whether oral or written. This LICENSE may only be modified in writing 
signed by an authorized officer of Proliphix. Customer agrees that it will not ship, transfer or export the 
SOFTWARE into any country, or use the SOFTWARE in any manner, prohibited by the United States 
Bureau of Export Administration or any export laws, restrictions or regulations.

Содержание NT10e

Страница 1: ...s Network Thermostat Configuration Guide NT10e and NT20e Release 3 0 Part No 600 01000 201 Rev 1 June 2007 Inside Configuring the thermostat using the TDI Configuring the thermostat using the TMI Trou...

Страница 2: ...Proliphix Inc All other trademarks are the property of their respective owners This document contains information that is the property of Proliphix Inc This document may not be copied reproduced reduc...

Страница 3: ...NS No Reverse Engineering Customer may not reverse engineer decompile or disassemble the SOFTWARE nor attempt in any other manner to obtain the source code No Separation of Components The SOFTWARE is...

Страница 4: ...N LOSS OF BUSINESS INFORMATION OR ANY OTHER PECUNIARY LOSS ARISING OUT OF THE USE OF OR INABILITY TO USE THE SOFTWARE EVEN IF PROLIPHIX HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OTHER If any...

Страница 5: ...have all original and unaltered markings and labels serial numbers model numbers etc of manufacture This limited warranty does not cover the repair of cracked scratched broken or modified plastics ot...

Страница 6: ...d MA 01886 The RMA number must be clearly marked on the outside of the package Products received without an RMA number or without shipping prepaid will be subject to refusal by Proliphix Proliphix res...

Страница 7: ...en 2 6 Sensor Status Screen 2 8 Status Control Screen 2 9 Thermostat Control Screen 2 10 Thermostat Status Screen 2 12 Alarm Status Screen 2 13 Network Status Screen 2 14 Chapter 3 Configuring the The...

Страница 8: ...600 01000 201 Rev 1 Advanced Settings Page 3 30 Sensor Settings Page 3 35 Remote Access Page 3 38 Remote Server Configuration 3 38 Remote Discovery Status Page 3 41 Usage Counters Page 3 42 Password S...

Страница 9: ...3 7 Figure 3 2 Administrator Authentication Window 3 8 Figure 3 3 Status and Control Page 3 9 Figure 3 4 General Settings Alarms and Alerts Pending Page 3 13 Figure 3 5 Setback Schedules Page 3 17 Fig...

Страница 10: ...2 7 Alarm Status Screen Options 2 13 Table 3 1 Thermostat Status Field Descriptions 3 10 Table 3 2 General Settings Field Descriptions 3 14 Table 3 3 In Out or Away Class Schedule Field Descriptions...

Страница 11: ...anaging multiple devices remotely in small or medium size buildings multiple buildings or corporate environments As a reader of this guide you should be familiar with the use of an Internet browser fo...

Страница 12: ...guring Proliphix devices For a detailed description of each guide see Proliphix Documentation Library page xiii 1 2 3 Installing the Thermostat Proliphix Thermostat Installation Guide Proliphix Ethern...

Страница 13: ...uthentication at the Proliphix web site TM220e h and TM250e h Thermal Managment Series Network Thermostat Configuration Guide TM220e h and TM250e h For customer who want to access and control their Pr...

Страница 14: ...which you supply values courier italics Options and arguments for which you supply values Information that the user must enter Courier Bold font Screen messages or system output Courier Regular font S...

Страница 15: ...and serial number Type of heating cooling system for example gas oil or electric warm air hot water heat pump steam or gravity Location and number of wires attached to the Proliphix thermostat To cont...

Страница 16: ...ace Proliphix Welcomes Your Comments You can mail email or fax your comments Please include the document part number in the subject line of your email or fax message E mail techpubs Proliphix com Fax...

Страница 17: ...Draft Confidential 1 Overview The Proliphix Basic Series Network Thermostats are powered by a Proliphix Ethernet Power Adapter EPA The end user of the Basic Series Thermostats should consult the Prol...

Страница 18: ...hix thermostats through your web browser Thermostat Device Interface The buttons on the front of the thermostat enable you to modify the temperature enable basic HVAC functions and to view the thermos...

Страница 19: ...P address and port number using the Thermostat Device Interface buttons and control on the front of the thermostat 1 From the Status Control Screen page 2 9 select the Network Status Screen page 2 14...

Страница 20: ...Thermostat Configuration Guide Release 3 0 Part No 600 01000 201 Rev 1 CHAPTER 1 Overview What s Next Continue with Chapter 2 Configuring the Thermostat Using the TDI or Chapter 3 Configuring the The...

Страница 21: ...reen options on the thermostat The thermostat s front panel includes up and down arrows and several buttons located at the bottom of the LCD to select the desired configuration settings Thermostat But...

Страница 22: ...tton multiple uses screen sensitive Selects the function displayed on the LCD Middle button multiple uses screen sensitive Selects the function displayed on the LCD Right button multiple uses screen s...

Страница 23: ...t Configuration Guide Release 3 0 2 3 Part No 600 01000 201 Rev 1 Each thermostat displays content on the LCD screen The LCD screen is organized into primary and secondary or sub screens This section...

Страница 24: ...2 Thermostat Screen Options Field Description Zone Name network host name Initially the Zone Name is set to the last six digits of the network MAC address e g 00 00 6A Network Connectivity When visibl...

Страница 25: ...lly remove the Hold after which the temperature settings Return to that set in the schedule The Hold button toggles between Hold and Return See Advanced Settings Page on page 3 30 HVAC Activity Displa...

Страница 26: ...ude Auto The fan is controlled by either the heat or AC systems or both On Forces the fan to the on state independent of the heat or AC systems Fan Control Displays the options for changing the state...

Страница 27: ...HVAC settings at the thermostat Figure 2 5 Changing the HVAC Setting 1 2 3 4 5 6 Select the middle HVAC button to enter the HVAC mode Select the middle Mode button to modify HVAC or fan settings Use...

Страница 28: ...he sensor status screen display options Note The NT10e does not support external thermal sensors therefore this screen is not available on the NT10e Network Thermostat Table 2 4 Sensor Status Screen O...

Страница 29: ...Screen page 2 10 Thermostat Status Screen page 2 12 Alarm Status Screen page 2 13 Network Status Screen page 2 14 Figure 2 7 Status Control Screen Table 2 5 lists the Status Control screen options Ta...

Страница 30: ...on this screen This screen also displays the status of the selected type along with the default settings To change specific parameters for each type go to the Advanced Settings Page page 3 30 To init...

Страница 31: ...anging the HVAC Setting page 2 7 or Status Control Page page 3 9 Fuel Burner Fossil fuel systems which includes oil or gas fired boilers or furnaces Heat Pump Electric heat pump HVAC system type See t...

Страница 32: ...mostat Status Screen The Thermostat Status screen is a sub screen of the Status Control Screen page 2 9 This screen displays the following information for each thermostat Current date Product model nu...

Страница 33: ...Temp Limit Temperature below which an alarm indication is set by the thermostat OK Temperature of thermostat has not dropped below that set as Low Temperature Limit Not OK Temperature of thermostat ha...

Страница 34: ...twork Status Screen The Network Status is a sub screen of the Status Control Screen page 2 9 This screen displays the following information Thermostat host name Unique Ethernet Media Access Control MA...

Страница 35: ...the Thermostat Management Interface TMI Thermostat Management Interface TMI Authentication The TMI for all Basic Series thermostats requires password authentication prior to accessing the HTML pages t...

Страница 36: ...uter supports DHCP then your Proliphix thermostat automatically retrieves an IP Address Gateway Address and Subnet Mask from the DHCP server on your network Before you Begin Before you access the TMI...

Страница 37: ...r thermostat s should automatically communicate with the local DHCP server and be assigned a unique IP address 2 Go to the physical location of each thermostat and record the following information usi...

Страница 38: ...1 Log in to the TMI as follows Username admin Password admin default 2 Access the General Settings Page page 3 13 through the TMI 3 Enter a Device Name and Site Name for example the name or location...

Страница 39: ...t number in your browser window For example http 192 168 111 100 80 Where 192 168 111 100 is a unique IP address initially assigned via DHCP and 80 is the default Proliphix assigned Web HTTP port numb...

Страница 40: ...n page 3 7 A yellow banner at the top of each page contains the following information for each thermostat Model number Page title Host name of the thermostat Each thermostat page also includes browser...

Страница 41: ...ime the default Status Control Login page appears Proliphix recommends that you log in to the thermostat from this page The thermostat s status is visible to you without logging in but you must log in...

Страница 42: ...s TMI pages 1 Click Login The login window appears See Figure 3 2 Proper authentication is required before you can access any other thermostat TMI pages Figure 3 2 Administrator Authentication Window...

Страница 43: ...on Guide Release 3 0 3 9 Part No 600 01000 201 Rev 1 Status Control Page The TMI displays the default Status Control page after authentication The Status Control page displays a snapshot of most of th...

Страница 44: ...s disabled if the HVAC mode is set to Heat or Off See HVAC Mode page 3 11 This field is not visible if the thermostat is configured to be a heat only controlling device See Advanced Settings Page page...

Страница 45: ...ntrol neither system Off The thermostat is disabled from controlling either the heating or cooling system Heat Heating system only Cool Cooling system only Auto Automatic changeover between heating an...

Страница 46: ...nfigured limit before resetting this alarm See General Settings Page page 3 13 OK No High Temperature alarm exists Alert The temperature monitored within the thermostat has risen above the pre set hig...

Страница 47: ...Guide Release 3 0 3 13 Part No 600 01000 201 Rev 1 General Settings Page The General Settings page contains parameters and settings that enable you to configure the thermostat name and location and s...

Страница 48: ...ure Scale Select either the Fahrenheit or Celsius temperature scales Fahrenheit default All thermostat temperature readings and reporting are displayed in the Fahrenheit temperature scale F Celsius Al...

Страница 49: ...set 30 F 34 5 C to 200 F 93 C This is a major red alarm condition See Figure 3 4 on page 3 13 High Temp erature Dismiss If a High Temp Limit alarm is pending you must clear this condition In Figure 3...

Страница 50: ...rmostat date and time marking the time of the beginning of the filter change interval This date is set after clicking Submit with the Filter Replaced check box checked e g If a 30 Runtime Days interva...

Страница 51: ...e 3 0 3 17 Part No 600 01000 201 Rev 1 Setback Schedules Page The Proliphix thermostat supports a set of scheduling options that you can configure through the TMI to create customized heating or cooli...

Страница 52: ...cooling settings to provide periodic air flow The TMI supports the following three Day Classes shown in Figure 3 6 Figure 3 6 Day Class Scheduling Each Day Class supports the following four non overl...

Страница 53: ...ekly Schedule In Figure 3 5 on page 3 17 the Default Weekly Schedule table provides a template that you can use to apply the three day classes to each day of the week for every week of the year The TM...

Страница 54: ...Occupied Unoccupied Other Class Schedule Pages From the In Out or Away Class Schedule page you can assign both heat and cool temperature settings in each of the four schedule Periods Figure 3 7 shows...

Страница 55: ...Away Class Schedule Field Descriptions Field Description Period Displays one of four time periods of the day Time Use the drop down menu to modify the time period in 15 minute increments Includes AM...

Страница 56: ...ree Day Classes see Figure 3 6 on page 3 18 to each of the seven days of the week Figure 3 8 Default Weekly Schedule Page Use Table 3 4 to assign Day Classes to each day of the week Table 3 4 Default...

Страница 57: ...very Monday through Friday as In and you want to schedule a national holiday or a company shutdown go to the Schedule Special Days page 3 23 and configure the day s or week s as Away schedule This all...

Страница 58: ...ecial Days entry in the table You can enter this information in the Special Days table using either of the following methods Click directly on the date on the Calendar View See Figure 3 5 on page 3 17...

Страница 59: ...schedule from the December 23 2007 through December 29 2007 Figure 3 11 Special Days Table Page Example 2 For example to add a week long holiday period 1 Click Edit Special Days from Figure 3 5 on pa...

Страница 60: ...k Thermostat Configuration Guide Release 3 0 Part No 600 01000 201 Rev 1 CHAPTER 3 Configuring the Thermostat Using the TMI The Setback Schedules Page now displays the two Special Days entries in the...

Страница 61: ...de Release 3 0 3 27 Part No 600 01000 201 Rev 1 Network Settings Page From the Network Settings page you can configure the appropriate network parameters specific to your local network such as configu...

Страница 62: ...e a permanent IP address assignment for remote access or for simplified local access IP Address Displays the unique Internet Protocol address either assigned statically or by DHCP See IP Address Metho...

Страница 63: ...standard IP port number designation The default port number is 80 LAN Auto Discovery Broadcast Port Allows you to specify to which port the thermostat responds to queries when interrogated by the Devi...

Страница 64: ...ed Settings Page The Advanced Settings page enables you to customize the thermostat by selecting the HVAC type and setting heating and cooling parameters How you configure your thermostat depends on t...

Страница 65: ...ttings Page Basic Series Network Thermostat Configuration Guide Release 3 0 3 31 Part No 600 01000 201 Rev 1 Figure 3 15 shows the Advanced Settings page for a Fuel Burner HVAC system Figure 3 15 Adva...

Страница 66: ...If Your HVAC System is a Fuel Burner Heat Control Select the HVAC control for this thermostat This parameter describes the thermostat capability to control a fuel burner heating system The thermostat...

Страница 67: ...1 5 2 0 2 5 3 0 C Second stage heat temperature offset from first stage heat set point temperature Cool Control Specifies the HVAC control of this thermostat This parameter describes the thermostat s...

Страница 68: ...es required between the completion of a cooling cycle and the next subsequent cooling cycle The default delay is 3 minutes Fan on Heat Controls the fan state during heating cycles In most HVAC applica...

Страница 69: ...ev 1 Sensor Settings Page From the Sensor Settings page you can add external thermal sensors and configure zone temperature thermal averaging of the Local or the two Remote Sensors Figure 3 16 Sensor...

Страница 70: ...s excluded from the thermal averaging calculations Enable default The internal thermal sensor participates in the algebraic averaging The Zone Temperature now reflects the average temperature of the a...

Страница 71: ...disabled Enable Remote Sensor 1 2 is included in the thermal averaging calculations The Zone temperature now reflects the average temperature of the averaged measurements Sensor Correction Select the...

Страница 72: ...are sent to the Proliphix Web Server IP address for processing and subsequent transmission as an e mail Remote Server Configuration You can access the Proliphix Network Thermostats remotely from anywh...

Страница 73: ...Remote Server either the Proliphix Remote Management Server See the Proliphix Installer Remote Management Guide or a private server to provide remote access capability Remote Server Configuration Ser...

Страница 74: ...the last intercommunication between the thermostat and the remote server If there is a good communication connection between the thermostat and the remote server the server deems that the thermostat i...

Страница 75: ...te Access Page page 3 38 the Remote Discovery Status Page page 3 41 appears This page displays a brief synopsis of the state of the thermostat and initiates the discovery process with the remote web s...

Страница 76: ...a minute accurate duration activity for all relays Each counter directly accumulates the number of minutes each relay has been active Only the Admin istrator account can reset the current value for e...

Страница 77: ...Cool1 relay minute activity counter The Admin account user can reset this field by setting Reset Counters in the Last Counter Reset field Fan Displays the Fan relay minute activity counter Can be rese...

Страница 78: ...etwork Thermostat Configuration Guide Release 3 0 Part No 600 01000 201 Rev 1 CHAPTER 3 Configuring the Thermostat Using the TMI Password Settings Page As a user you may change your password at any ti...

Страница 79: ...Admin Password Settings page fields Table 3 10 Admin Password Settings Field Descriptions Field Description Admin Password New Password Enter an alpha numeric password for the Administrator admin acco...

Страница 80: ...Beta Draft Confidential 3 46 Basic Series Network Thermostat Configuration Guide Release 3 0 Part No 600 01000 201 Rev 1 CHAPTER 3 Configuring the Thermostat Using the TMI...

Страница 81: ...ay be necessary to bring the thermostat back into proper operation Software Reset A software reset reboots the network processor and retains the programming and thermostat setback schedules To perform...

Страница 82: ...he Proliphix Thermostat Installation Guide 2 Attach the top of the cover to the top of the base as a hinge 3 Press and hold the middle button of thermostat while closing the cover into the base Do not...

Страница 83: ...ay class 3 18 Default host name 3 3 Default weekly schedule 3 19 3 22 Device name zone name 3 3 DHCP See Dynamic Host Configuration Protocol 3 2 Down arrow 2 2 Dynamic Host Configuration Protocol 3 2...

Страница 84: ...2 8 Setback schedules page 3 26 Software reset 4 1 Special days 3 23 Status control page 3 7 3 9 Status control screen described 2 9 Subnet mask 3 28 T TDI See Thermostat Device Interface 1 2 Tempera...

Страница 85: ...Beta Draft Confidential Index Basic Series Network Thermostat Configuration Guide Release 3 0 Index 3 Part No 600 01000 201 Rev 1...

Страница 86: ...Index 4 Basic Series Network Thermostat Configuration Guide Release 3 0 Part No 600 01000 201 Rev 1 Index...

Отзывы: