Thermostat Screen
Basic Series Network Thermostat Configuration Guide, Release 3.0
2-11
Part No. 600-01000-201, Rev. 1
Use
Table 2-6
to configure the
Thermostat Status
screen options.
Table 2-6 Thermostat Status Screen Options
Field
Description
Reset
Press and hold the Reset button for three (3) seconds to perform a software reboot.
Type
Select either
Fuel Burner
(default) or
Heat Pump
. When selecting between either
Fuel Burner
or
Heat Pump
or between
Heat Pump
and
Fuel Burner
, the
HVAC
Mode
must be set to
OFF
prior to selecting the opposite setting. (See
Changing the
HVAC Setting (page 2-7)
or
Status & Control Page (page 3-9)
.
Fuel Burner
– Fossil fuel systems which includes oil or gas-fired boilers or
furnaces.
Heat Pump
– Electric heat pump HVAC system type.
See the
Advanced Settings Page (page 3-30)
further explanation of the following parameters.
HVAC Type
Displays the selected HVAC system type; Fuel Burner or Heat Pump.
Fuel Burner
:
Heat Ctrl:
Disable
– No heating system is present.
Enable
– Heating is enabled.
Cool Ctrl:
Disable
– No cooling system is present.
Enable
– Cooling is enabled.
Heat Pump
:
Heat Ctrl:
Disable
– No heating system is present (i.e. air conditioning only)
Enabled
- Heating is enabled.
Aux Heat
– Auxiliary heat is enabled to augment the heat pump.
Cool Ctrl:
Disable
– No cooling system is present (i.e. heat only)
Enabled
– Heating is enabled.