PIPE CONNECTIONS
w
Connect the rigid descending pipes and the fi ltration group as illustrated in the diagram
below. The fi ltration kit supplied with your pool is sized for installation of the fi ltration
group 3.5 m from the pool, pipe and tube lengths are indicative. They will need to be
modifi ed as a function of your pool confi guration. Make sure that you calculate and cut
the various lengths as a function of the rolls of tubing provided.
w
Open the various valves to fi ll the hydraulic circuit with water. Check for leaks.
w
Before starting the pump (the pump should never be allowed to run ‘dry’) check that
the pre-fi lter has fi lled with water. If necessary, open the pre-fi lter and fi ll it and the
skimmer with water to facilitate priming of the pump.
w
Turn the 6-way valve to Back wash (to clean the fi lter before starting fi ltration.
See page 74).
w
Start the pump and check for leaks again.
CAUTION
If the pool is to
installed in-ground,
check for leaks before
burying the lines and
connections.
FILLING THE WATER SYSTEM
aspiration
refoulement
1
2
3
4
POOL 3x6
1 = return
length = +/- 14,1 m
2 = return Y length = +/- 0,7 m x2
3 = skimmer length = +/- 2,9 m x2
4 = vacuum point length = +/- 6,6 m
w
Once all the connections have been carried out, cut out the liner as described on page
70 and fi nalise installation of the underwater lights as described on page 71.
w
Check that all the valves are closed and fi ll the pool until the water level
is 2/3 of the way up the skimmer mouth.
Figure 44
POOL 4x8
1 = return
length = +/- 17,2 m
2 = return Y length = +/- 1,4 m x2
3 = skimmer length = +/- 3,1 m x2
4 = vacuum point length = +/- 6,8 m
POOL 5x10
1 = return
length = +/- 20 m
2 = return Y length = +/- 2,5 m x2
3 = skimmer length = +/- 3,3 m x2
4 = vacuum point length = +/- 7 m