background image

You have chosen 

a CLEARWATER

®

salt chlorinator 

by ZODIAC because it makes life

stress-free and relaxed.

The LM2 is a pole reversal

model. The electrodes are 

self-cleaning to minimise your

maintenance time.

Processing is non-stop and

reduces maintenance to a simple

check of the water pH levels.

Thank you for purchasing 

our CLEARWATER

®

water 

processing system, we recommend

that you read these instructions

carefully before installing 

and using it.

c

o

n

t

e

n

t

s

How does your CLEARWATER® system work ?        

13

The controls on your CLEARWATER® system           

13

Indicators and buttons  

13

Installation          

Installation of the cell  

15

Installing the control box                                             

15

How to connect the control box to the cell

15

How to connect the control box to the pump

15  

Usage recommendations          

Filtering times  

16

Water balance 

16

Standard maintenance checks 

18

Maintenance of your CLEARWATER® system          

Cleaning the electrodes  

19

Damage caused by insects 

19

Solutions to possible problems                         

20

Warnings                                                   

21

Your guarantee                                              

21

Содержание ClearWater LM2

Страница 1: ...instructions carefully before installing and using it c o n t e n t s How does your CLEARWATER system work 13 The controls on your CLEARWATER system 13 Indicators and buttons 13 Installation Installat...

Страница 2: ...to right maximum Press it once more and it goes back to the minimum G Super chlorination Used for rapidly increasing the chlorine in the swimming pool on a one off basis To do this leave the filter p...

Страница 3: ...rsal cycle is 5 8 hours C Super chlorination Indicator lit up this is indicating that the super chlorination function has been selected It will go out as soon as the super chlorination process has fin...

Страница 4: ...efore re starting the pump and the CLEARWATER system Fix the control box to a wall within 1 5 m from the cell and 1 2 m above the ground respecting safety regulations in terms of the distance from the...

Страница 5: ...at your chlorinator is operating at its optimum the water balance must be regularly checked and maintained Salinity 4 kg of salt per m3 pH 7 2 to 7 6 Chlorine stabiliser 40 to 75 g per m3 TAC total al...

Страница 6: ...linity value measured at least 24 hours afterwards is back down to between 8 and 12 French It is preferable for correct operation that the TH be no higher than 30 Fr 300 ppm To soften the water use th...

Страница 7: ...salt in the water Check the TAC Check the level of chlorine stabiliser Backwash We recommend that you set the production rate of your electrolyzer to minimum when carrying out a backwash of the filte...

Страница 8: ...enough time for the calcium scale to dissolve When the electrodes have been cleaned remove the solution N B This cleaning solution can be purchased from your specialist swimming pool dealer To make it...

Страница 9: ...ue sensor is not connected The unit has been stopped Or the power supply has been cut or a fuse has blown SOLUTIONS Set the pH between 7 2 7 6 Check that the electrodes are clean Check the stabiliser...

Страница 10: ...and concern for quality has been used in the construction of our equipment It is subjected to numerous quality controls Our models are regularly updated and improved to make the most of technological...

Отзывы: