Every week :
> Visual inspection of the electrodes: remove the foreign bodies that have
come through the filter and sometimes remain stuck in the body of the cell.
Be careful not to deform or scratch the electrodes.
> Check the level of free chlorine.
> Check the pH.
> Check the sand filter, and clean it if necessary (
backwash*
).
> Check the pump’s pre-filter
Every month :
> Check the level of salt in the water.
> Check the TAC.
> Check the level of chlorine stabiliser.
*Backwash :
We recommend that you set the production rate of your electrolyzer to
minimum when carrying out a backwash of the filter. If your prefer to turn it
off and isolate it during the backwash, we recommend that you disconnect
the blue wire on the sensor. The appliance will then remain switched-off and
will ignore the re-start command sent by the pump.
In this case, remember to re-connect the blue wire on the sensor once you
have finished your maintenance operation.