State indicates the current state of the program, eg. loading, ready, non-existent etc. A list of
possible states is given below. The states and the corresponding numbers, conform exactly to the
states for the download domain used by The Manufacturing Message Specification.
State
Explanation
0
Non-existent
No program in this memory type or program
segment. (MMS = Non-existent)
1
Loading
Download in progress. (MMS = Loading)
2
Ready
The program is ready to be selected to run.
(MMS = Ready)
3
In-use
This program is selected in ProgramControl. The
state change to/from In-use is entirely controlled
in ProgramControl. Download is not allowed.
(MMS = In-use)
4
Complete
The program is completely downloaded and will
change state to ready. (MMS = Complete)
5
Incomplete
An error has occurred during download and the
program state changes to Non-existent.
(MMS = Incomplete)
14
Deleting
Deletion in progress, eg. clearing Flash.
(MMS = Deleting)
LibraryIndex is identical to LibraryControl.LibraryIndex.
MaxLibraryIndex indicates the max. number of programmes which can be, or are stored in, the
program channel. One type of memory and only one program can be implemented in the PD 3260
module. MaxLibraryIndex therefore always reads 1.