Page 67
box).
7516
GPS Trimble
Settings
No connection
to GPS receiver
available
Check GPS settings and network
connection.
7530
Camera error
Camera not
connected
Make sure the camera is connected
correctly.
7531
Camera error
No camera
available
Make sure the camera is connected
correctly.
7540
Data serial port error
Cannot open
data serial or
COM port
Make sure the COM port is not blocked by
another program.
7550
Data serial port error
Cannot write to
data serial port
Select the right COM port in the app
settings.
7610, 7620
Write XLS header
error
Unable to write
parameters to
specified
measuring file
Make sure the measuring file exists and
you have write permission. Make sure the
measuring file is not opened by another
program like MS Excel.
7630
Write parameter
error
Unable to write
parameters to
specified
measuring file
Make sure the measuring file exists and
you have write permission. Make sure the
measuring file is not open in another
program like MS Excel.
7660
Calibration Error
Calibration
Error
The R
L
calibration value is either 0 or not
a defined number. Probably the marking
preset is not defined well for the current
marking.
7661
Load speed
calibration error
Speed
calibration
values could not
be loaded
Make sure the measuring head is
connected to the software. Restart the
system.
7662
Save speed
calibration error
Speed
calibration
values could not
be saved
Make sure the measuring head is
connected to the software. Restart the
system.
7663
State machine error
State Machine
cannot be put
into idle state
Restart the system.
12 Technical specification
Observation distance:
30 m, according to CEN-geometry, equivalent
Observation angle:
EN 1436: 2.29°
ASTM E1710: 1.05°
Illumination angle:
EN 1436: 1.24°
ASTM E1710: 88.76°