Page 43
Edit Filter Settings:
Enable editing filter settings
PassFailFilterSettings
Upper and lower limit for valid R
L
values. Taken from the current Marking
Presetting, see chapter 5.8.1 on page 37. Values outside of limits are discarded.
•
PassFail:
Enable / disable filter
•
Pass Fail min:
Lower limit, R
L
not valid if lower, default = 40
•
Pass Fail max:
Upper limit, R
L
not valid if higher, default = 1000
Marking width filter
Maximum and minimum width of a valid marking. Taken from the current
Marking Presetting, see chapter 5.8.1 on page 37. Instead of millimetres, the
width given here is in bars. A bar represents one channel of the sensor, its width
in the measuring field is approx. 1.5 cm (100 cm / 64 = 1.5 cm). Values outside
of limits are discarded.
•
Marking width filter:
Enable / disable filter
•
Min width in bars:
Lower limit, marking not valid if lower
•
Max width in bars:
Upper limit, marking not valid if higher
MarkingGapsFilter
Number of gaps (in bars) allowed within and between markings.
•
GapsFilter:
Enable / disable filter
•
Allowed Gaps within:
Number of gaps allowed within a marking
•
Max Gaps between:
Number of gaps allowed between two markings
ToleranceBandFilterMarkingDetection
Max difference (tolerance band) of R
L
value in % between best and worst
marking when measuring double or triple lines
•
ToleranceBandFromTopIn%:
Tolerance band in %, default = 50
ToleranceBandFilterSingleMarking
Max difference (tolerance band) of R
L
value in % between best and worst
channel when measuring single lines
•
ToleranceBandFilter:
Enable/disable filter
•
ToleranceBandFromTopIn%:
Tolerance band in %, default = 25
RoadStudFilter
Road stud detection
InterruptedMarkingMask
Interrupted marking filter