Page 38
Settings Name:
Name of the marking presetting
Trigger Mode:
Automatic Meters (distance based, default) or
Automatic Seconds (time based for stationary wet
measurements). Indicates the distance or time
interval for calculating the average R
L
value in the
measurement file
Average every:
Interval length (meter or seconds), depending on
the trigger mode.
Interval length in meter: 10
– 10.000 m
Interval length in seconds: 1
– 1.000 s
Nr. of expected Markings:
Number of markings that will be detected (1, 2 or 3)
Expected min width:
Minimum width of marking. Markings less wide will
not be measured (default: 80)
Expected max width:
Maximum width of marking. Wider markings will not
be measured (default: 280)
R
L
Pass/Fail min value:
Minimum R
L
value of a marking, lower values will
be stored as 0 in the measuring file (default: 40)
R
L
Pass/Fail max value:
Maximum R
L
value of a marking, higher values will
be stored as 0 in the measuring file (default: 1000)
Cam trigger low value:
Picture will be taken if R
L
is lower
Cam trigger high value:
Picture will be taken if R
L
is higher
5.8.2 General settings
The language can be changed in the general settings, click on “General” in the
settings window to open the general settings window:
Language:
Language
Beep on Error:
Beep if error occurs
GPS Model:
Trimble LAN (default)