PRIMERGY BX600 Management Blade Hardware Guide
●
10. Turn on/off all server blades (1_3_10)
Sets the power supply of all the installed Server Blades.
2. NIC Detection Timeout
❑
0
–
300
Sets the time (seconds) for NIC status detection. If
communication does not take place in the setting time
here, a NIC status self diagnostic test is performed.
Note:
Set the timeout of server monitoring software such as ServerView
to a time longer than that of the "NIC Detection Timeout". For
details about setting timeout, refer to the manuals attached to the
server monitoring software products.
If an error is detected by "NIC Status Detection", the status of the Management Blade will become
"critical" but the management error LED will not blink or light up.
Parameter
Contents
1. Turn on all server blades
The power supply of all the installed Server Blades is turned on sequentially.
2. Turn off all server blades
Select and the "Confirmation" screen appears. Select "Yes, turn off all Server
Blades" and "off" or "graceful shutdown and off" will be ordered sequentially
for the "Server power" of all the installed Server Blades. For details about
"Server power", refer to " 1. Server power" (
When performing Server Blade power setting in this section, after ordering power ON/OFF, check in
the CLI display etc. that all power ON/OFF operations have been completed and move on to the
next operation.
Parameter
Setting
Contents
+--------------------------------------------+
| |
+--------------------------------------------+
Turn on/off all server blades page_1_3_10
(1) Turn on all server blades
(2) Turn off all server blades
Enter selection or type (0) to quit: